4.
Unscrew cable fi tting nut, pass RS485 wires
through and resecure the nut.
5.
Pass wires through center slot on bracket.
6.
Use a fl at head screwdriver to install the wires from
the automation system. Match the colors to the
wires already installed from the power pack.
7.
Once connection has been made, the User Interface
(UI) should display
"Standby ‡".
Use Copper Conductors Only
Rated for 90°C Minimum
CIRCUIT BREAKER
PANEL
120 VAC
NEUTRAL
GROUND
Pool Pump
120 VAC
Figure 6.
Wiring Diagram with a 120 VAC Filter Pump
Use Copper Conductors Only
Rated for 90°C Minimum
CIRCUIT BREAKER
PANEL
240 VAC
GROUND
Pool Pump
Figure 7.
Wiring Diagram with a 240 VAC Filter Pump
|
Installation & Operation Manual
POOL PUMP CONTROL
12
9
3
6
LINE 1
TO EARTH
BONDING POINT
POOL PUMP CONTROL
12
9
3
6
LINE 2
LINE 1
TO EARTH
BONDING POINT
ENGLISH
8.
Follow the instructions for your automation system
to continue with device set up and schedules.
9.
Once proper communication is confi rmed, reinstall
the RS485 connector bracket into the
power pack body.
10. If proper communication is not established begin
with step 3 and retrace the above steps.
11. If communication is still not established please call
technical support at 800-822-7933.
NOTE
The TruClear does not capture a salinity reading from
your pool. When connected to an automation system,
the target salinity level of 3000ppm will be displayed.
"General Error" will show as a result of low salt, low
temp or a combination of both.
POWER PACK
POWER PACK
NOTE: VIOLET AND WHITE WIRES
ARE NOT USED FOR 240VAC WIRING
Page 15
TO EARTH
BONDING POINT
TO CELL
TO EARTH
BONDING POINT
TO CELL