6.

Installation Clearances

Before installing, check for the following:
Install in accordance with relevant building and mechanical codes, as well as any local, state
or national regulations.
Item
• Maintain the following clearance from
both combustible and non-combustible
materials.
• If the unit will be installed in the vicinity of a
permanent kitchen range or stove that has
the possibility of generating steam that
contains fats or oils, use a dividing plate or
other measure to ensure that the unit is not
exposed to air containing such impurities.
* The dividing plate should be of noncombust-
ible material of a width greater than the
water heater.
• If possible, leave203mm( 8") or more on
either side of the unit to facilitate inspec-
tion.
• If possible, leave 610mm(24") or more in
front of the unit to facilitate maintenance
and service if necessary.
40
Check
Caution
Illustration
305mm (12" Indoor )
914mm (36" Outdoor)
50mm(2" Indoor)
610mm(24" Outdoor)
Exhaust hood
Dividing plate
Range
203mm
(8") or
more
203mm
(8") or
more
610mm
(24") or
more
610mm
(24" Outdoor)
102mm
(4" Indoor)
Water
heater
Min:76mm (3")
Min:76mm (3")
(unit: inch)