heat recovery unit. In winter, however, the demand is for hot water production from the main heat exchanger and alternatively (assigning appropriate
priority) from the recovery exchanger.
The unit can run in two modes:
AUTOMATIC: the system allows total recovery of the condensation heat and/or the production of chilled water (summer season)
SELECT: this allows the production of hot water to the recovery heat exchanger or from the main one (winter season)
Summer season "AUTOMATIC"
Domestic
Air Conditioning
Hot water
Cold water
Competitive advantages
Its natural application and as a valid alternative in all conventional systems that require a chiller or heat pump with the use or integration of a boiler.
The advantages are due to a single unit being used, the economic saving due to the high COP (operating with heat recovery in summer mode), the
Fourth generation polyvalent versatile heat pump, which unlike other polyvalent units meets the typical demand in 2-pipe systems with a single unit
It is therefore offered on the market as the unit that guarantees fundamental aspects such as EFFICIENCY, RELIABILITY AND VERSATILITY.
1.1 Activation and deactivation of DS and RC100
The units (HEAT PUMPS) set up with total recovery RC100 can activate the thermal recovery by means of a set-point that can be set from a keyboard
on the machine or via external digital input (e.g. the KTRD accessory).
The units (CHILLERS) set up with DS desuperheater or total recovery RC100 and units (HEAT PUMPS) with DS desuperheater can activate the thermal
recovery by means of an external digital input (e.g. the KTRD accessory).
Moreover, the criterion to stop the thermal recovery can be established from the panel:
for digital contact: if the consensus is interrupted, the thermal recovery stops as well. This mode meets the requirement to carry out a temperature
control system of the storage tank connected to the recovery;
for maximum return temperature: the said limit is set from the panel on the machine or from the remote keyboard (KTR accessory). The recovery
recovery.
Section II :: Installation and maintenance
Winter season "SELECT"
Domestic or Air Conditioning
83
Hot water