THAEBY SE Model (single circuit)
Nominal cooling capacity (*)
EER
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Nominal heating capacity (**)
COP
Nominal heating capacity (**) (°) EN 14511:2013
COP (*) (°) EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Sound power with FNR accessory (****)(*)
Scroll/step compressor
Circuits
Fans
Heat exchanger
Water side heat exchanger nominal pressure drops (*)
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal heating capacity DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser inlet
air temperature 35°C; chilled water temperature
7°C; temperature differential at evaporator 5 K;
evaporator scaling factor equal to 0.35x10-4 m2
K/W.
(**) In the following conditions: Evaporator inlet
water temperature 7°C B.S., 6°C B.U.; hot water
temperature 45°C; temperature differential at
condenser 5 K; fouling factor equal to 0.35x10-4
m2 K/W.
(***) Sound pressure level in dB(A) referring to
directionality factor equal to Q=2. The noise data
Enclosed documents
2110
kW
100
2,71
4,44
kW
99,5
2,66
3,76
kW
112
3,09
kW
112,6
3,05
dB(A)
53
dB(A)
85
dB(A)
81
2/3
1
n° x kW
2x1,8
m³/h
39600
Type
m³/h
17,2
kPa
36
kPa
97
kPa
141
kPa
94
kPa
138
l
300
kW
132
m³/h/kPa
22,7/64
kW
26
m³/h/kPa
2,2/6
Kg
27
Kg
10,4
2110
kW
36,9
kW
36,3
kW
1,5/2,2
V-ph-Hz
V-ph-Hz
A
61
A
86
A
248
A
164
A
3,0/4,5
2110
mm
2440
mm
1350
mm
2650
Ø
2"½ vic
Ø
1" GM
Kg
1250
refers to the units without the electric pump
(****) Sound power level in dB(A) on the basis of
measurements taken in accordance with UNI EN-
ISO 9614 and Eurovent 8/1 Standards The noise
data refers to the units without the electric pump
(±) Recovery unit heating capacity Conditions
referring to the unit operating with chilled water
temperature 7°C, differential temperature due
to evaporation of 5 K, hot water temperature
produced equivalent to 40/45°C (RC100) 50/60°C
(DS). NB. With heat pumps operating in winter
mode with DC active, the heating capacity avail-
291
2120
2140
2150
111
124
143
2,71
2,7
2,73
4,44
4,47
4,37
110,4
123,4
142,3
2,66
2,65
2,68
3,78
3,80
3,73
123
139
158
3,11
3,11
3,08
123,7
139,7
158,8
3,08
3,08
3,04
54
54
55
86
86
87
82
82
83
2/3
2/2
2/3
1
1
1
2x1,8
2x1,8
3x1,8
38800
38800
59400
Plates/Shell and tube (STE accessory)
19,1
21,3
24,6
44
41
45
85
85
113
129
128
155
82
81
108
126
124
149
300
300
300
147
165
189
25,3/78
28,4/73
32,5/79
29
33
37
2,5/8
2,8/7
3,2/7
34
34
39
10,4
10,4
10,4
2120
2140
2150
41
45,9
52,4
39,5
44,6
51,4
1,5/2,2
1,5/2,2
2,2/3,0
400 – 3 – 50
230 – 1 – 50
68
76
87
96
104
121
266
266
347
182
182
232
3,0/4,5
3,0/4,5
4,5/6,0
2120
2140
2150
2440
2440
2440
1350
1350
1350
2650
2650
3600
2"½ vic
2"½ vic
2"½ vic
1" GM
1" GM
1" GM
1310
1320
1470
able is decreased from the portion supplied to the
desuperheater.
( ) Absorbed current/absorbed power value without
electric pump.
The starting current refers to the worst conditions of
the unit.
(°) Data calculated in accordance with EN
14511:2011 under nominal conditions.
The refrigerant charge values are indicative. Refer
to the serial number plate.
2170
2200
2220
160
183
207
2,7
2,7
2,7
4,38
4,48
4,35
159,3
182,2
206,1
2,65
2,66
2,66
3,74
3,78
3,69
176
197
228
3,09
3,1
3,1
176,9
198
229,1
3,06
3,07
3,07
56
56
57
88
88
89
84
84
85
2/2
2/3
2/2
1
1
1
3x1,8
3x1,8
4x1,8
59400
58200
79200
27,5
31,5
35,6
45
44
45
105
94
75
148
137
119
99
85
64
141
129
108
300
300
550
212
244
274
36,5/80
42/78
47,1/80
42
48
53
3,6/7
4,1/8
4,6/7
40
51
60
10,4
10,4
10,4
2170
2200
2220
59,3
67,8
76,7
56,9
63,6
73,4
2,2/3,0
2,2/3,0
2,2/3,0
98
113
127
134
149
168
360
375
390
245
252
270
4,5/6,0
4,5/6,0
4,5/6,0
2170
2200
2220
2440
2440
2440
1350
1350
1350
3600
3600
4550
2"½ vic
2"½ vic
2"½ vic
1" GM
1" GM
1" GM
1480
1565
1730
EN