Model TCAETY HE-A
Nominal cooling capacity (*)
EER
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Sound power with FNR accessory (****)(*)
Scroll/step compressor
Circuits
Fans
Heat exchanger
Water side heat exchanger nominal pressure drops (*)
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal heating capacity DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser inlet air temperature
35°C; chilled water temperature 7°C; temperature differential at
evaporator 5 K; fouling factor equal to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to a 10 m distance from
data refers to the units without the electric pump
(****) Sound power level in dB(A) on the basis of measurements taken
in accordance with UNI EN-ISO 9614 and Eurovent 8/1 Standards
The noise data refers to the units without the electric pump
Enclosed documents
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
kW
111
122
139
3,19
3,15
3,18
5,02
5,09
4,96
kW
110,5 121,5 138,4 156,4 175,4 200,3 223,2 241,3 276,3 309,1 345
3,13
3,1
3,13
4,28
4,32
4,13
dB(A)
55
56
57
dB(A)
87
88
89
dB(A)
79
79
80
2/3
2/3
2/2
1
1
1
n° x kW 2 x1,8 2 x1,8 3 x1,8 3 x1,8 3 x1,8 4 x1,8 4 x1,8 4 x1,8 6 x1,8 6 x1,8 8 x1,8
m³/h
41600 41600 59600 59600 62000 79200 79200 78000 104800 109800 132200
Type
Plates/Shell and tube (STE accessory)
m³/h
19,1
21
23,9
kPa
34
32
35
kPa
96
95
85
kPa
140
138
128
kPa
93
91
80
kPa
137
134
123
l
300
300
300
kW
141
156
176
m³/h/kPa
24,2/56 26,8/53 30,3/57 34,4/56 38,7/54 44/57 49,2/58 53,3/46 60,5/43 67,9/56 75,5/50
kW
28
30
34
m³/h/kPa 2,4/6 2,6/7 2,9/7 3,4/7 3,8/7 4,3/9 4,8/8 5,2/14 5,9/12 6,7/13 7,4/12
Kg
17
17
18
Kg
10,4
10,4
10,4
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
kW
34,8
38,7
43,7
kW
1,5/2,2 1,5/2,2 1,5/2,2 2,2/3,0 2,2/3,0 2,2/3,0 2,2/3,0 3,0/4,0 3,0/4,0 4,0/5,5 4,0/5,5
V-ph-Hz
V-ph-Hz
A
58
64
73
A
86
96
108
A
248
266
270
A
164
182
186
A
3,0/4,5 3,0/4,5 3,0/4,5 4,5/6,0 4,5/6,0 4,5/6,0 4,5/6,0 6,0/8,0 6,0/8,0 8,0/10,5 8,0/10,5
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
mm
2440 2440 2440 2440 2440 2440 2440 2030 2030 2030 2030
mm
1350 1350 1350 1350 1350 1350 1350 2090 2090 2090 2090
mm
3600 3600 3600 3600 4550 4550 4550 4800 4800 5300 5300
Ø
2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 3" vic 3" vic 3" vic 3" vic
Ø
1" GM 1" GM 1" GM 1" GM 1" GM 1" GM 1" GM 2" vic 2" vic 2" vic 2" vic
Kg
1090 1100
1110
(±) Recovery unit heating capacity Conditions referring to the unit
operating with chilled water temperature 7°C, differential temperature
due to evaporation of 5 K, hot water temperature produced equivalent
to 40/45°C (RC100) 50/60°C (DS). NB. With heat pumps operat-
ing in winter mode with DC active, the heating capacity available is
decreased from the portion supplied to the desuperheater.
( ) Absorbed current/absorbed power value without electric pump.
The starting current refers to the worst conditions of the unit.
(°) Data calculated in accordance with EN 14511:2011 under nominal
conditions.
The refrigerant charge values are indicative. Refer to the
serial number plate.
289
157
176
201
224
242
3,16
3,15
3,16
3,15
3,14
4,98
5,04
4,89
4,95
5,10
3,11
3,1
3,11
3,1
3,1
4,22
4,28
4,18
4,21
4,30
57
58
59
59
58
89
90
91
91
90
80
81
82
82
83
2/3
2/2
2/3
2/2
4/4
1
1
1
1
2
27
30,3
34,6
38,5
41,6
34
33
35
35
28
119
110
91
74
96
161
153
135
117
137
112
102
81
62
92
155
145
125
105
133
300
550
550
550
700
200
225
256
286
310
39
44
50
56
60
19
23
25
26
50
10,4
10,4
10,4
10,4
20,8
49,7
55,9
63,6
71,1
77,1
400 – 3 – 50
230 – 1 – 50
83
93
106
118
128
121
134
153
168
192
347
360
379
390
362
232
245
256
270
278
1130 1280 1300 1320
2290
EN
277
310
346
3,14
3,14
3,14
5,06
5,00
5,03
3,11
3,1
3,1
4,28
4,25
4,23
60
60
62
92
92
94
85
85
86
4/4
4/4
4/4
2
2
2
47,6
53,3
59,5
26
34
31
83
102
82
126
158
136
78
95
73
121
151
128
700
700
700
352
395
439
69
78
86
53
58
63
20,8
20,8
20,8
88,2
98,7 110,2
147
164
183
208
242
268
378
468
502
294
366
387
2390 2520 2640