Model THAEQY HE-A
Nominal cooling capacity (*)
EER
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Nominal heating capacity (**)
COP
Nominal heating capacity (**) (°) EN 14511:2013
COP (*) (°) EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Scroll/step compressor
Circuits
Fans
Heat exchanger
Water side heat exchanger nominal pressure drops (*)
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal heating capacity DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential
at evaporator 5 K; evaporator scaling factor
equal to 0.35x10-4 m2 K/W.
(**) In the following conditions: Evaporator
inlet water temperature 7°C B.S., 6°C B.U.;
hot water temperature 45°C; temperature dif-
ferential at condenser 5 K; fouling factor equal
to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to
directionality factor equal to Q=2. The noise data
refers to the units without the electric pump
Enclosed documents
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
kW
92
101
2,49
2,34
2,56
4,65
4,48
4,55
kW
91,6 100,6 118,6 130,6 144,5 169,5 187,4 206,5 238,4 270,3 302,3
2,46
2,31
2,53
4,01
3,82
3,87
kW
110
118
3,31
3,32
kW
110,5 118,5 136,5 153,6 171,6 194,7 221,8 236,7 266,7
3,28
3,29
3,27
dB(A)
47
47
dB(A)
79
79
2/3
2/3
1
1
n° x kW
2x0,6 2x0,6 3x0,6 3x0,6 3x0,6 4x0,6 4x0,6 4x0,6 6x0,6 6x0,6 8x0,6
m³/h
23900 23900 33900 33200 35400 45200 44200 45000 60600 63200 77000
Type
m³/h
15,8
17,4
20,5
kPa
26
24
kPa
109
109
kPa
153
153
kPa
107
106
kPa
151
150
l
300
300
kW
133
148
m³/h/kPa
22,9/55 25,5/50 28,4/55 32,7/55 36,5/52 42/57 47,3/57 52,4/45 59/43 67,8/53 75/50
kW
24
28
m³/h/kPa 2,1/5 2,4/6 2,8/7
Kg
38
39
Kg
10,4
10,4
10,4
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
kW
37
43,2
46,5
kW
33,2
35,5
41,2
kW
1,5/2,2 1,5/2,2 1,5/2,2 2,2/3,0 2,2/3,0 2,2/3,0 2,2/3,0 3,0/4,0 3,0/4,0 4,0/5,5 4,0/5,5
V-ph-Hz
V-ph-Hz
A
61
72
A
81
91
A
243
261
A
159
177
A
3,0/4,5 3,0/4,5 3,0/4,5 4,5/6,0 4,5/6,0 4,5/6,0 4,5/6,0 6,0/8,0 6,0/8,0 8,0/10,5 8,0/10,5
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
mm
2440 2440 2440 2440 2440 2440 2440 2030 2030 2030 2030
mm
1350 1350 1350 1350 1350 1350 1350 2090 2090 2090 2090
mm
3600 3600 3600 3600 4550 4550 4550 4800 4800 5300 5300
Ø
2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 3" vic 3" vic 3" vic 3" vic
Ø
1" GM 1" GM 1" GM 1" GM 1" GM 1" GM 1" GM 2" vic 2" vic 2" vic 2" vic
Kg
1420 1450 1460 1540 1710 1730 1820
(****) Sound power level in dB(A) on the basis of
measurements taken in accordance with UNI EN-
ISO 9614 and Eurovent 8/1 Standards The noise
data refers to the units without the electric pump
(±) Recovery unit heating capacity Conditions
referring to the unit operating with chilled water
temperature 7°C, differential temperature due
to evaporation of 5 K, hot water temperature
produced equivalent to 40/45°C (RC100) 50/60°C
(DS). NB. With heat pumps operating in winter
mode with DC active, the heating capacity avail-
able is decreased from the portion supplied to the
desuperheater.
296
119
131
145
170
188
2,45
2,37
2,42
2,37
4,54
4,44
4,46
4,49
2,42
2,34
2,39
2,35
3,87
3,78
3,81
3,79
136
153
171
194
221
3,3
3,28
3,29
3,26
3,29
3,26
3,26
3,23
3,26
48
48
49
50
50
80
80
81
82
82
2/2
2/3
2/2
2/3
2/2
1
1
1
1
1
Plates/Shell and tube (STE accessory)
22,5
24,9
29,2
32,3
27
26
25
27
26
100
137
132
116
106
143
178
173
160
150
96
133
126
108
96
139
173
168
152
140
300
300
550
550
550
165
190
212
244
275
32
35
40
46
51
3/5
3,4/6
4/8
4,4/6 4,9/13 5,6/11 6,4/11 7/10
40
51
64
65
79
10,4
10,4
10,4
10,4
53,5
61,2
70,3
79,3
46,6
52
59,5
67,2
400 – 3 – 50
230 – 1 – 50
77
89
102
117
132
102
115
128
144
159
264
341
354
370
381
180
226
239
247
261
( ) Absorbed current/absorbed power value with-
out electric pump.
The starting current refers to the worst conditions
of the unit.
(°) Data calculated in accordance with EN
14511:2011 under nominal conditions.
The refrigerant charge values are indicative. Refer
to the serial number plate.
207
239
271
303
2,32
2,47
2,36
2,4
4,65
4,64
4,66
4,60
2,3
2,45
2,34
2,38
3,98
3,94
3,94
3,93
236
266
300
341
3,14
3,13
2,97
3,1
301 341,9
3,12
3,11
2,95
3,08
51
53
53
54
83
85
85
86
4/4
4/4
4/4
4/4
2
2
2
2
35,6
41,1
46,6
52,1
20
20
25
24
117
105
130
113
157
146
187
169
114
101
125
106
154
142
182
163
700
700
700
700
305
343
394
436
57
65
74
81
79
82
91
95
20,8
20,8
20,8
20,8
89,2
96,8 114,8 126,3
75,2
85
101
110
148
161
191
210
183
195
229
251
353
365
455
485
269
281
353
370
2600
2700 2850 2970

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Winpack he-a se tcaey b-s 2120Winpack he-a se tcaey b-s 2140Winpack he-a se tcaey b-s 2150Winpack he-a se tcaey b-s 2170Winpack he-a se tcaey b-s 2200Winpack he-a se tcaey b-s 2220 ... Afficher tout

Table des Matières