12. Warranty Period

The Cavitron® 300 Series Ultrasonic Scaler is warranted for THREE YEARS from date of purchase. The Steri-Mate 360 Handpiece
enclosed with your system is warranted for SIX MONTHS from date of purchase.

WARRANTY STATEMENT

Dentsply Sirona Cavitron products are designed expressly for dental use, and this warranty is not applicable to other uses. The products
are warranted against defects arising from faulty materials or workmanship from date of purchase for the period stated above. Parts will
be repaired or replaced at the discretion of Dentsply Sirona.

WARRANTY TERMS

This warranty extends to Cavitron products purchased from an authorized Dentsply Sirona distributor, and only to the original
purchaser. The Warranty is subject to the following conditions:
1.
The product must be registered online using the instructions provided with your system within four(4) weeks of date of purchase.
2. Any installation or routine servicing of Cavitron product must be performed by Dentsply Sirona Cavitron Care
authorized Dentsply Sirona distributor service personnel.
3. Any warranty repair must be performed by Dentsply Sirona Cavitron Care
4. Cavitron Systems and handpieces must not be subjected to abuse or improper installation or operation.
5. Cavitron Ultrasonic Inserts are subject to these additional terms:
a. Inserts must not be subjected to abuse, improper use or application, including, but not limited to, bending and reshaping.
b. Inserts must not be subjected to improper cleaning, disinfection or sterilization procedures.
c. Warranty will not be honored for inserts used in units other than Cavitron units.
6.
The use of any inserts other than Cavitron will void the warranty on Cavitron Ultrasonic Scaling Systems.
There are no warranties, express or implied, which extend beyond the description on the face hereof. Dentsply Sirona neither
assumes, nor authorizes any person to assume for it, any other liability in connection with the sale or use of its products. Damages
are limited strictly to repair or replacement of parts. Dentsply Sirona expressly disclaims liability for incidental and consequential
damages resulting from the use of the products.
Claims covered by this warranty will be honored when presented through your Dentsply Sirona distributor within thirty (30) days from
discovery of defect within the applicable warranty period.
Service or
SM
Service.
SM
English - 15

13. Specifications

Electrical Voltage
Continuous (100-240 VAC)
Current
1.0 Amperes, Maximum
Phase
Single
Frequency
50/60 Hertz
Water Pressure
20 to 40 psig (138 to 275 kPa)
Water Temperature
< 25°C (77°F)
Water Flow Rate
Minimum Setting (CCW) < 15 ml/min
Maximum Setting (CW) > 55 ml/min
Weight
4.4 lbs (2 Kg)
Dimensions
Height: 3.7 in (9.4 cm)
Width: 6.9 in (17.5 cm)
Depth: 10.7 in (27.2 cm)
Handpiece Cable length: 6.5 ft (2.0 M)
Auxillary Footswitch Cable length: 10 ft. (3.0 M)
Water Supply Line length: 8 ft (2.4 M)
Footswitch
Protection Class IPX1.
Not for operating theatres.
Remote Communication
Frequency: 2.4 GHz
Power: < 1mW
Temperature:
Operating Environment
15 to 40 Deg Celsius
(59 to 104 Deg Fahrenheit)
Relative Humidity:
30% to 75% (non-condensing)
Transport and Storage Conditions
Temperature:
-40 to 70 Deg. Celsius
(-40 to 158 Deg. Fahrenheit)
Relative Humidity:
10% to 95% (non-condensing)
Atmospheric Pressure: 500 to 1060 hPa