Honda EU26i Manuel De L'utilisateur page 40

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.Switch on the equipment to be used.
The Output indicator (green) will light.
In case of normal operation
OUTPUT INDICATOR
(GREEN)
• In case of overload operation (refer to page 33) or when trouble
occurs for the equipment being used, the Output indicator (green) will
go out, the Overload indicator (red) will light continuously, and no
power will be put out.
At this time, the engine will not stop, so that the engine must be
stopped by setting the respective engine switch to STOP.
NOTE:
• The Overload indicator (red) also lights in the following cases:
When the inverter is overheated; the current to the connected
appliance will be shut off. Check to see if the air intake is obstructed.
• When equipment requiring a large starting power, like a motor etc., is
used, the Overload indicator (red) and the Output indicator (green)
may light together for a short time (about 4 sec), but this is no
abnormality. After start of the equipment, the Overload indicator (red)
will go out and the Output indicator (green) will stay lit.
• When the operation of one generator is to be stopped after start of
the equipment, the special cable/receptacle for parallel operation also
must be removed at the same time.
7.When electric power is to be taken again from the generator, switch
off the equipment to be used and remove the plug from the AC
receptacle. Confirm that the equipment and the connection are
normal and that not too much power is to be taken, and then start
the engine.
In case of overload operation or short-circuit
OVERLOAD INDICATOR
(RED)
37