Electrical Connection; Accessories; Maintenance; Adjustment Of Run Time - DAB GENIX VT Instructions Pour L'installation Et La Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Installation in accordance with Plumbing Code of Australia and
AS/NZS3500.

4. ELECTRICAL CONNECTION

Make sure that the product is suitable for the supply voltage and
frequency available at the installation site.The electrical connec-
tion must be carried out in accordance with local regulations.
The product must be earthed.
The installation must include an earth leakage circuit breaker for
protection against earth fault currents. Thisensures protection
when using a Schuko plug or another plug with earth pin.The
product must be connected to a mains switch with a minimum
contact gap of 3 mm in all poles.In case of overtemperature, a
thermal switch cuts out the motor and cuts it in automatically when
it has cooled sufficiently.

5. ACCESSORIES

1- An alarm device for acoustic alarm in case of malfunction or high level
in the tank is available as an accessory (noise level 75 dB(A)). Product
number: 60166477.
2- A kit containing: a hose (length 500mm) with adapter, available as an
accessory. Product code 60168126
1
2

6. MAINTENANCE

The system does not require any particular maintenance, but we recom-
mend checking the operation and couplings of the pipes at least once a
year.

6.1 Adjustment of run time

The default setting ensures proper operation in most pipework. If the pipe-
work is particularly long or short, it may be necessary to adjust the run
time.
6.2 Service instructions
Thanks to the product design, service is easy in case of malfunction or
blocked pump.
Digits in the following sections refer to the pictures in the appendix
bleshooting".
Before carrying out any service work, remove the fuse, pull out
the plug, or switch off the power supply. Make sure that the pow-
er supply cannot be accidentally switched on.All rotating parts
must have stopped moving.The product must only be serviced by
trained service personnel.
Impeller stuck
1. Disconnect the power supply
2. Remove the motor cover cap.
3. Insert a screwdriver (min. 110 mm) through the plug hole and into the
slot of the shaft end.Turn the shaft right and left to free the impeller from
dirt.
GB
ENGLISH
"Trou-
11

Publicité

Table des Matières
loading

Table des Matières