SIGFOX PULSE - Mode d'emploi / User guide version V1.5.1
3. Radio frames
The SIGFOX PULSE transmits raw information from meters using the SIGFOX network
This section contains information you can use to decode the frame as well as the location in the frame of information concerning the meter or
meters associated with the SIGFOX PULSE.
3.1. Frame format
•
SIGFOX EUROPE
•
RF data rate : 100bps
•
Uplink payload : up to 12 bytes
•
Downlink payload : up to 8 bytes
3.1.1 Uplink
PPayload uplink up to 12 bytes, data format : Little endian, low significant byte first.
Frame types :
•
Code 0x00 : reserved
•
Code 0x02 : pulse counter index
•
Code 0x03 : device configuration
•
Code 0x04 : pulse counter n° 1 configuration
•
Code 0x05 : pulse counter n° 2 configuration
Unsignificant bytes are not transmitted (X)
0
1
2
Code
Status
0x00
Cf Status
Channel 1
0x02
Cf Status
Type
Device
0x03
Cf Status
Type
0x04
Cf Status
Pulse weight 1
0x05
Cf Status
Pulse weight 2
3.1.2 Status
Product status.
•
Low bat error = 1 if supply voltage <= 2.5 V, else 0
•
Configuration switch error = 1 if no switch consistency, else 0
•
HW error = 1 if hardware failure, else 0
•
Configuration done = 1 if last downlink frame was a right frame and configuration done, else 0
Alarm/Status
Bit7
Frame counter
No error
Low bat error
Configuration
Switch error
HW error
Configuration
done
3
4
Index1 (LSB First)
Expressed in 1 W.h, 0.1L or 0.1 dm3
Channel
Transmit period
On/Off
Bit6
Bit5
0x0 à 0xF
5
6
7
PAYLOAD
RESERVED
Channel 2
Type
Channel
Channel 2
1 Type
Type
Memo Index 1
Memo Index 2
Bit4
Bit3
HW
0
0
0
1
0
8
9
10
Index2 (LSB First)
Expressed in 1 W.h, 0.1L or 0.1 dm3
Pulse
Memo
Input
X
switch
type
X
X
Bit2
Bit1
Switch
Low bat
0
0
0
1
1
0
0
0
0
0
11
X
Bit0
Configuration
0
0
0
0
1
Page
39