2.4. Configuring the SIGFOX PULSE

Your SIGFOX PULSE is configured via the combination of switches. The following settings can be changed:
The meter type
The pulse width
The transmission frequency
Note: configuration via switches lets you use 2 meters of the same type (2 water, 2 gas, ...).
CONFIGURATION TABLE:
Parameter
Value
Electricity
Water
Meter type
Gas
Heat
1L / 10dm
10L / 10dm
Pulse width
100L / 100dm
1000L / 1m
2 frames per day
50 frames per day
Transmission frequency
100 frames per day
140 frames per day
PLEASE NOTE: You must set your switches before activating the meters. Once the fraud wire for each of the meters has been installed and the
SigFox PULSE has been started via magnet, the configuration with the switchs can no longer be possible.
If the configuration has any difference between the switchs and the product register value, the consistency error bit will be set to on in the
frame. This consistency verification is carried out every minute.

2.5. Closure of the case

Once steps 3.2, 3.3 and 3.4 have been completed, you can close the SIGFOX PULSE's case.
Procedure:
Make sure the seal is installed correctly on the case plate.
SW1
ON
OFF
OFF
ON
3
/ 1Wh
3
/ 10Wh
3
/ 100Wh
3
/ 1000Wh
SW2
SW3
SW4
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Seal
SW5
SW6
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Page
33
of 41