SIGFOX PULSE - Mode d'emploi / User guide version V1.5.1
1.4. Technical Specifications
1.4.1 General characteristics
Parameters
Power supply voltage
Power supply
Operating temperature
Dimensions
Case
SIGFOX Certification
Radio standards
1.4.2 Product input tolerance characteristics
Parameters
Min. pulse width
Max. pulse frequency
Max current (open collector version)
Input resistance (dry contact version)
Max. voltage
1.4.3 Battery life
Conditions of use
Product storage before use:
1 year maximum.
Calculations carried out at
a temperature of 20°C
1.4.4 Operating modes
SIGFOX PULSE has three states (modes) of operation.
•
STANDBY: this is the mode in which you receive your product (no transmission of radio frames).
•
OPERATION: this is the mode in which SIGFOX PULSE transmits frames periodically. To switch to this mode of operation, you need to
activate the product with a magnet (see §2.6 Product start-up).
Value
3.6 V nominal
Integrated Li-SOCl2 battery (radio management and querying of meters)
-25°C / +70°C
105 x 50 x 27mm
IP 67
SIGFOX Certification number : P_001F_D8E8_02
EN 300-220, EN 301-489
Value
8ms
33Hz
1mA
1kOhm
3.6V
Transmission frequency
140 frames per day
140 frames per day
100 frames per day
100 frames per day
50 frames per day
50 frames per day
20 frames per day
20 frames per day
2 frames per day
2 frames per day
Number of meters
1
2
1
2
1
2
1
2
1
2
battery life
0.5 year
0.5 year
0.7 year
0.7 year
1.3 year
1.3 year
3 years
3 years
+10 years
+10 years
Page
30
of 41