Télécharger Imprimer la page

VOLTCRAFT AM-39X14/TEMP Mode D'emploi page 2

Publicité

Les langues disponibles

Les langues disponibles

OPERATING INSTRUCTIONS
AM-39X14/TEMP
PANEL METER
ITEM NO.: 10 30 72
INTENDED USE
The product features a dial from -50 °C to +50 °C and is ideal for use in a temperature
indicator. External wiring may be necessary, depending on application. Only in integrated
status the product may be put into operation. The suitable regulations are to be observed. The
scale needle can be adjusted precisely with the screw. The product is only to be connected to
DC circuits. Observe the technical data for this!
For safety and approval purposes, you must not rebuild and/or modify this product. If you use
the product for purposes other than those described above, the product may be damaged.
In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc.
Read the instructions carefully and keep them. Make this product available to third parties
only together with its operating instructions.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
DELIVERY CONTENT
• Meter
• Operating instructions
SAFETY INSTRUCTIONS
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the
warranty/guarantee.
a) Persons / Product
• The fixed measuring instrument must not be used for medical purposes.
• Be especially cautious in dealing with voltage >35 V/DC. Already at this voltage
you can get a life-threatening electric shock when touching electric lines.
• The device must not be used in damp interiors or outdoors in the open air.
• Be sure not to exceed the maximum permissible measurement range. You must
observe the technical data.
• De-energise the electric system before installing the measuring instrument.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protect it from any accidental use. Safe operation can no longer be guaranteed if
the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
can damage the product.
• Also observe the safety and operating instructions of any other devices which are
connected to the product.
b) Miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the
device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
If you are not sure about the correct connection or use, or if questions arise which are not
covered by these operating instructions, please do not hesitate to contact our technical
support or another qualified specialist.
Voltcraft®, Lindenweg 15, D-92242 Hirschau, Tel. +49 180/586 582 7.
INSTALLATION
Assembly and installation may only be carried out by a specialist, who is
familiar with the relevant regulations and the ensuing risks.
Carefully attach the measuring instrument. You can get the corresponding dimensions (in
mm) from the following sketch.
39.0
35.0
VERSION 03/13
CONNECTION
In order to ensure a correct start of operation, you should read these
operating instructions including the safety instructions thoroughly and
attentively before using the device.
Do not connect when the wires are live.
Connection of the panel meter has to be done in series connection. Connect the panel meter
to both + and - solder terminals on the back. You must observe the correct polarity to avoid
damaging the product.
DISPOSAL
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the relevant
statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
TECHNICAL DATA
Dial .................................................... -50 °C to +50 °C incl. zero centre position
Measurement range
(full-scale deflection) .......................... ±250 µA
Internal resistance ............................. 6 50 Ω
Max. current-carrying capacity .......... 1 mA
Accuracy ............................................ ±5 %
Movement .......................................... Moving coil
Installation dimensions ...................... 35 x 14 mm
Electrical connection .......................... Soldered connection
Weight ............................................... approx. 11 g
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2013 by Voltcraft®
33.0
22.0

Publicité

loading

Ce manuel est également adapté pour:

103072