Warm-up humidifier
7
Check the FiO
Start the FiO
Options" on page 16). Follow the instructions on the display.
8
Check pulse oximeter (if in use).
Attach the accessories according to the setup descriptions (see "Attaching the pulse
oximeter" on page 7). From the Monitoring menu page go to the Monitoring screen. Check
that the values for SpO
9
Check oxygen connection (if in use).
Attach the accessories according to the setup descriptions (see "Adding supplemental
oxygen" on page 7).

Starting therapy

CAUTION
The Clinical mode
press the power switch
1
Fit your patient interface (mask or catheter mount) as described in the user instructions.
2
Lie down and arrange the air tubing so that it is free to move if you turn in your sleep or
arrange the tubing so it is comfortable in your wheelchair.
3
To start treatment, press
into your patient interface and treatment will begin.

Stopping therapy

You can stop therapy at any time, simply remove the patient interface and press
airflow or if SmartStart/Stop is enabled, simply remove the patient interface, and treatment
will stop automatically.
Notes:
• SmartStop may not work if Full face or Trach is selected as mask type; the High Leak
alarm or the Low Min Vent alarm is enabled; "Confirm Therapy Stop" is enabled; or the
mask-fitting feature is running.
• When the device is stopped and operating in standby mode with an integrated
humidifier connected, it will continue to blow air gently to assist cooling of the
humidifier's heater plate.
• Masks with high resistance (eg, pediatric masks) may cause the operation of the
SmartStop feature to be restricted.
• When using with oxygen, turn off oxygen flow before stopping therapy.
12
monitoring sensor (if in use).
2
sensor calibration. Select Setup menu, then Options (see "Setup menu:
2
and Heart rate are displayed.
2
is only for clinicians. If the device is operating in clinical mode
to re-start the device in patient mode
or if the SmartStart/Stop function is enabled, simply breathe
You can use the warm-up feature to pre-heat
the water in the humidifier prior to starting
treatment. The humidifier will be automatically
detected when the device is turned on. The
Treatment screen provides the option to start
warming the humidifier. If the humidifier is
heating, the related symbol is displayed at the
top of the LCD screen.
For more information, see the H4i User Guide.
Note: The H4i in heating mode can only be used
when the device is connected to mains supply.
.