Table des Matières

Publicité

Button TC6 (Auto ASC)
Activates/deactivates the automatic ASC function.
In this mode, motor speed increases or decreases depending on the
quantity of smoke and odours being produced under the hood. When the
function is active, BL6 becomes active.
Each time that the motor changes speed, either automatically or forced by
the user, BL6 lighting blinking for a few seconds.
30h filter ALARM
After 30 hours of operation, an alarm switches on to signal the need for
anti-grease filter cleaning.
The filter alarm, when active, is displayed for 30 sec each time the motor is
deactivated:
BL6 remains ON.
During this period, it is possible to reset the alarm by pressing the TC6
button for longer than a second.
120h filter ALARM
After 120 hours of operation, an alarm switches on to signal the need for
active carbon filter (optional) replacement.
The filter alarm, when active, is displayed for 30 sec each time the motor is
deactivated:
BL6 lighting blinking.
During this period, it is possible to reset the alarm by pressing the TC6
button for longer than a second
Buttons TC5 + TC6 (ASC sensitivity)
ASC odour sensor sensitivity can be varied on 4 different levels as needed
by pressing buttons TC5 and TCS simultaneously for more than 1 second.
The motor must be OFF and automatic function NOT active.
When sensitivity setting function is activated:
all BL switch OFF (no display) then BL6 activates FIX.
After 1 second, the BL2-BL5 LEDs will show the set sensitivity value, BL2
for lower sensitivity up to BL5 which indicates higher sensitivity. You can set
a different value using corresponding keys TC2, TC3, TC4 or TC5. To save
the new sensitivity, press TC6 or wait until the function deactivates
automatically.
It can be varied on your keyboard (for cleaning) with a long press of the
buttons TC1 and TC6 simultaneously. When the cleaning mode is active,
the keys TC1 and TC6 remain lit. To exit cleaning is necessary to activate
the buttons again TC1 and TC6 pressed simultaneously (long), or wait for 5
minutes.
Work Time Limit
If the hood is left on (lights and/or motor), after 10 hours in the absence of
commands from the user, it will automatically switch to OFF condition with
all services switched off.
Buzzer
The Buzzer emits a "beep" each time that a command is set from the
keyboard or remote control (optional)
Key L: light switch. Key A : B = Motor ON/OFF switch - Speed I
Key 2: B = Motor ON/OFF switch - Speed I
Key 3: B = Motor ON/OFF switch - Speed I
Key 4: B = Motor ON/OFF switch - Speed I
Filter alarm: after about 30 hours of operation, with the motor off, the speed
keys (keys 1, 2, 3 and 4) flash for 30 seconds to indicate the anti-grease
filters need cleaning. After cleaning the anti-grease filters (and/or replacing
the charcoal filters), restart the hour counter (RESET) by pressing key C
during filter alarm display. Timer 5'; the timer can be started (switch-off
delayed by 5 minutes) by pressing one of the speed keys for 2 seconds
(key 1, 2, 3 or 4) when the motor is running; the selected speed key starts
flashing.
Key L: light switch.
Key 1: activates/deactivates the sensor (AUTOMATIC or MANUAL mode). In
Automatic mode the sensor is active
and the speed of the motor increases or decreases depending on the smoke.
- signals the filter alarm (with motor off)
Key 2: Motor ON/OFF switch - Speed I
Key 3: Motor ON/OFF switch - Speed II
Key 4: Motor ON/OFF switch - Speed III
Filter alarm: after about 30 hours of operation, with the motor off, the speed
keys (keys 1, 2, 3 and 4) flash for 30 seconds to indicate the antigrease filters
need cleaning. After cleaning the anti-grease filters (and/or replacing
the charcoal filters), restart the hour counter (RESET) by pressing one of the
speed keys for 2 seconds during filter alarm display.

SENSOR SENSITIVITY

When the sensor is on, the hood automatically starts working when any
smell, vapour, smoke or heat is detectedduring cooking. The sensor sensitivi-
ty can be changed according to need. For example: very sensitive when
using an electric hob or little sensitive when using a gas hob. Change the
sensitivity by simultaneously pressing key L and key 1. The sensitivity
selected will be set. Using the keys 2,3,4 you can set the desired sensitivity.
Store the new sensitivity by pressing key 1.
Button A: Turns the lights on/off. If held down for about 2" when the filter alarm
is active, it resets the hour counter.
Button B: Activates/deactivates the "Automatic" function. Light S – Filter
alarm: When the light comes on, it indicates
that 30 h of use have elapsed; it remains on for 30". When the light S flashes,
it means that about 120 h of operation
have elapsed. The filter reset is indicated only when the motor is off, both in
manual and automatic mode.
Automatic operation with sensor:
When the button B is pressed, the automatic function is activated. This is
indicated by the corresponding LED coming
on. When the LED B flashes, it means that the sensor is waiting for data.
Modifying sensor sensitivity:
While in manual mode and with the motor off, simultaneously press the
buttons B and C. At this point, the set sensitivity is indicated by the LED C, D
or E coming on. To set the desired sensitivity press one of the buttons C, D
or E (min, med, max). Press B again to store it.
Press button B once again to go to manual mode.
Operation as traditional hood:
If in automatic mode, press the button B to change to manual mode; the LED
B goes off.
Press one of the buttons C, D or E to start the motor in 1st, 2nd or 3rd speed,
respectively. Hold the same button
down for 2" to turn off the motor.
S
A
B
C
D
E

Publicité

Table des Matières
loading

Table des Matières