► Set the desired duty cycle 9 :
Five time settings are possible: approx. 20 sec. /
approx. 1 min / approx. 5 min / approx. 15 min /
approx. 30 min.
► Pulse output 9 :
Set up the controller
pulse mode (e.g. for the activation of a staircase
relay) ON: approx. 1 second / OFF: approx. 9 seconds.
The listed duty cycles are approximate values and are
subject to technical deviations.
Fine sensitivity settings
Carefully open the front cap.
Set the sliding switch 7 to the AUTO position.
Fine adjustment of the range detection  with the
„METER" adjustment screw between the positions „-"
and „+".
„-" smallest possible detection range
„+" largest possible detection range
Function test
The function test serves to test the motion sensor for
proper detection function in the desired installation
location.
In order to perform the function test, set the arrow 9 to
the „test" position.
, meaning the output is in
To do this, make the following settings:
Set the sliding switch 7 to AUTO.
Turn the METER adjustment screw  to the „+" position.
Turn the TIME adjustment screw 9 to the „test" position.
The twilight detection is deactivated.
Correctly install the motion sensor and connect it to the
mains voltage 4 5 .
Begin the function test  from outside of the probable
detection range and pass through the detection range
transversally until the motion sensor switches.
The LED  and the connected consumer switch for 2
seconds.
Adjust the „METER" adjustment screw  until the desi-
red detection range is set.
Repeat the function test  until a satisfactory result
is achieved.
