Faulty activation
In order to prevent faulty activation, the installation lo-
cation should be located at least 1 m from a light.
Movements (e.g. vibration) of the device have the same
D
effects as movements in the detection range (e.g. trees,
shrubs) and can trigger faulty activation.
For this reason, solid device installation is therefore ne-
cessary.
GB
Sensor exhibits
The motion sensor exhibits the most dependable de-
NL
tection behavior when the detection range is passed
through transversally 2 and not frontally 3 to the mo-
tion detector. (see Illustrations)
F
I
P
18
2
Electrical connection
Strip the insulation from the connecting wires for ap-
prox. 6-8 mm 4 and connect as follows:
See wiring diagrams 5 .
• Phase L (black) on terminal L.
• Neutral wire N (blue) on terminal 2 x N.
• Connecting/lamp wire (brown) on terminal L↑.
• For remote switching (manual override / Manual
ON), connect the external button to terminal T.
• For Master/Slave function, connect the terminals P
of the motion sensors with each other.
4
5
IC
3
6-8MM