9.2.8 Emergency Off
The welding process has been interrupted by pressing the STOP/RESET key.
9.2.9 Heater Coil Error
The current value during welding differs by more than 15% from the nominal value, indicating a short-
circuit in the heater coil.
9.2.10 Power Supply Failure
The last welding is incomplete. The welding unit was cut from power supply voltage. Confirm this mes-
sage by pressing STOP/RESET.
®
10
ROWELD
ROFUSE Basic 48 Technical Specifications
Operating Range
Nominal Voltage
Frequency
Power
Protection Index
Primary Current
Ambient Temperature
Output Voltage
Max. Output Current
Report Memory
Measuring Tolerance:
Temperature
Voltage
Current
Resistance
See section 7 for details on the specifications of the printer interface.
11

Service and Repair Contact

Rothenberger Werkzeuge GmbH
Industriestr. 7
65779 Kelkheim
Germany
24
Fittings up to 315 mm
230 V
50 Hz - 60 Hz
2800 VA, 80 % duty cy.
IP 54
16 A
- 10 °C to + 60 °C
8 V - 48 V AC
90 A
500 reports
± 5%
± 2%
± 2%
± 5%
Ph.: +49 (0)6195 80 01
Fax: +49 (0)6195 744 22
Web: www.rothenberger.com