EdilKamin ELLE Installation, Usage Et Maintenance page 14

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
The stove is delivered on a pallet inside a cardboard box.
First of all, remove the stove from its packaging, check
that the model is the one ordered, and make sure it has not
been damaged during transportation. Any complaints must
be made to the carrier (in writing on the accompanying
consignment note) upon receipt. Refer to the local regula-
tions in the country of use for assemby and anything else
not expressly shown. In Italy, refer to standard UNI
10683/2006, along with any regional or local health autho-
rity regulations. If the stove is to be installed in a condo-
minium, consult the administration before installing.
COMPATIBILITY WITH OTHER DEVICES
According to the regulation UNI 10683/05, the stove must
NOT be installed in the same room as extractors, type B
gas equipment or any device creating vacuum conditions.
Warning: extraction fans operating in the same room
can cause problems.
AIR INTAKE
The room of installation must have a suitable outside air
intake with a through surface area of at least 200 cm² (Ø
16), in order to replenish the burnt oxygen and ensure an
adequate combustion air flow.
The ELLE and VOGUE models only are available with the
possibilty of conveying air drawn from outside, by means
of a Ø 10 pipe to be connected directly to the rear of the
stove, as indicated in fig.2.
To connect the pipe to the stove, eliminate the pre-carved
cap (see fig.1) and fit the pipe by means of a "spring wire"
clamp, then fasten the pipe.
fig. 1
fig. 2
INSTALLATION
SAFETY DISTANCES
- Place the stove away from flammable materials and objects;
leave a distance of 80 cm from furniture and at least 10 cm
from the wall. These distances are for furniture or walls which
are either fireproof or able to withstand being raised to an envi-
ronmental temperature of 80°C without overheating to the
point of catching fire. The air circulation which is created
around the stove thanks to these distances ensures efficient
ventilation and improves thermal efficiency.
- In the event the stove is to be installed on a floor made with
a flammable material, we recommend placing it on a steel
plate available as an optional.
EDILKAMIN declines any responsibility for installations not
complying with the laws in force and for misuse of the stove.
SMOKE DUCT
The smoke duct connects the smoke outlet to the flue inlet.
The smoke duct must be made with steel or ceramic rigid
pipes.
Flexible metal pipes or fibre-cement pipes are not allowed.
Horizontal and counterslope sections should be avoided. Any
cross-secion change should be made in correspondence of the
stove outlet and not at the flue inlet.
Angles greater than 45° are not allowed (see figures 1,2,3,4
page 13).
The connection between the smoke duct and the steel flue
should be sealed with high temperature resistant mastic.
FIRE DAMPERS (with installation of the
damper on the smoke channel)
The fire damper should be easily handled and its position must
be distinguished from the outside through the adjustment
knob.
The fire damper must remain fixed in its position and must not
be able to close automatically.
The fire dumper must NOT close the flue section completely,
but it must guarantee a permanent minimum opening which
should be equal to 3 % of the section itself and in any case
equal to at least 20 cm².
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

RollerVogue

Table des Matières