3.2 AIR CONNECTION

Best use for connection of the compressor to an air circuit a flexible hose, to isolate
vibrations from the machine.

4.0 FIRST USE

1. Check if the instructions mentioned above have been executed.
2. Installing the air filter (L): before use you have to install the supplied air filter in the
cylinder head.
3. Assemble wheels + vibration damper in accordance with drawing:
4. Switch on the compressor by means of the pressure switch (A). The compressor
will now operate, unless the air receiver is still under pressure (K). Switch the
machine, during operation, exclusively off by means of the button on the automatic
pressure switch (A); the pressure circuit will be vented and the compressor can
start again uncharged.
5. Avoid the use of extension cables. If you use them, unroll them completely and use
cables of sufficient capacity. Table for extension cables:
0 - 10 meter: 3 x 1 1/2 mm
10 - 25 meter: 3 x 2 1/2 mm

5.0 OPERATION

1. The automatically operating compressor will stop at a pressure of 8 bar. When air
is used again and the pressure in the tank falls to 6 bar, the compressor will start
again.
2. Most pneumatic machines are suitable for an operating pressure of about 6 bar.
For some applications this pressure is even lower. To be able to set the right
pressure, a reducing valve can be mounted on the compressor (optional). This
valve can set the pressure of the air receiver (of course never higher than the
pressure in the air receiver).
3. Two extra plugs (I) are fitted to the tank, which can be used to get an extra
pressure connection.
Remove the dust cap and screw the air filter (L) in.
2
2
17