Setup; Ac Power; Ac Plug; Fuse Replacement - Chauvet Professional Maverick MK2 Profile Manuel D'utilisation

Masquer les pouces Voir aussi pour Maverick MK2 Profile:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Setup

3. Setup

AC Power

Each Maverick MK2 Profile has an auto-ranging power supply that works with an input voltage range of
100 to 240 VAC, 50/60 Hz. To determine the power requirements (circuit breaker, power outlet, and wiring)
for each Maverick MK2 Profile, refer to the label affixed to the product. You can also refer to the
Technical Specifications
The listed current rating indicates the maximum current draw during normal operation. For more
information, download Sizing Circuit Breakers from the Chauvet website:
Always connect the product to a protected circuit (a circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, completely disconnect the
product from power via breaker or by unplugging it during periods of non-use.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.

AC Plug

The Maverick MK2 Profile comes with a power input cord terminated with a Seetronic Powerkon A
connector on one end and an Edison plug on the other end (US market). If the power input cord that came
with your product has no plug, or if you need the change the plug, use the table below to wire the new plug.
Connection
AC Live
AC Neutral
AC Ground

Fuse Replacement

1.
Disconnect the product from power.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating
(F 12 A, 250 V).
4.
Screw the fuse holder cap in place and reconnect power.
Disconnect the product from the power outlet before replacing the fuse. Always replace
a blown fuse with one of the same type and rating.
Maverick MK2 Profile User Manual Rev. 3
chart in this manual.
Wire (U.S.)
Black
White
Green/yellow
www.chauvetprofessional.com
Wire (Europe)
Brown
Blue
Green/yellow
Screw Color
Yellow/brass
Silver
Green
Page 5 of 209

Publicité

Table des Matières
loading

Table des Matières