3. Setup

AC Power

The Maverick MK2 Spot has an auto-ranging power supply that works with an input voltage range of 100 to
240 VAC, 50/60 HZ. To determine the power requirements for each Maverick MK2 Spot, refer to the label
affixed to the product. You can also refer to the
The listed current rating indicates the maximum current draw during normal operation. For more
information, download Sizing Circuit Breakers from the Chauvet website:
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure
the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, completely disconnect the
product from power via breaker or by unplugging it during periods of non-use.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.

AC Plug

The Maverick MK2 Spot comes with a power input cord terminated with a True 1 compatible connector on
one end and an Edison plug on the other end (US market). If the power input cord that came with your
product has no plug, or if you need the change the plug, use the table below to wire the new plug.
Connection
AC Live
AC Neutral
AC Ground

Fuse Replacement

1.
Disconnect the product from power.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove the blown fuse from the holder and replace with another fuse of the same type and rating
(F 10 A, 250 V).
4.
Screw the fuse holder cap back in place and reconnect power.
Disconnect the product from the power outlet before replacing the fuse. Always replace
the blown fuse with another of the same type and rating.
Page 5 of 189
Technical Specifications
Wire (U.S.)
Black
White
Green/yellow
chart in this manual.
www.chauvetprofessional.com
Wire (Europe)
Brown
Blue
Green/yellow
Maverick MK2 Spot User Manual Rev. 11
Setup
Screw Color
Yellow/brass
Silver
Green