Use Coolant Accumulator - Dometic ColdMachine 50 Instructions De Montage Et De Service

Groupe frigorifique
Masquer les pouces Voir aussi pour ColdMachine 50:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 60
Coldmachine
9

Use coolant accumulator

9.1
Display and control elements of devices with
TEC program control
No. in
fig. 2,
Explanation
page 3
1
Green LED: Indicates that the compressor is working.
2
Yellow LED: indicates that the external power supply is present (voltage is
higher than 13.5 V or 27.0 V).
The LED flashes if the external power supply is too low (voltage ≤ 10.7 V or
21.7 V. Version E: ≤ 10.7 V or 22.0 V).
3
Red LED: indicates that the accumulator is being discharged because
the discharge button has been pressed
Low voltage shutdown (voltage ≤ 10.7 V or 21.4 V. Version E: ≤ 10.7 V or
22.0 V).
4
Accumulator discharge button: interrupts compressor operation until
the stored cold energy is exhausted
The external supply voltage level is restored after low voltage.
5
Temperature selector: allows the temperature in the cooling area to be set
as required
Min. (left limit) = warmest setting
Max. (right limit) = coldest setting
6
Main switch: for switching the cooling device on and off.
Position 0 = OFF
Position – = ON
9.2
Accumulator function
The accumulator function ensures that cold energy is stored automatically (up to
8 hours) if enough electrical power is available, for example when supplied by a
mains adapter.
Stored cooling power is discharged
• automatically when the switch-off voltage is reached (see the table on page 18)
• or manually by pressing the discharge button (fig. 1 A2 or fig. 2 4, page 3).
EN
Use coolant accumulator
27

Publicité

Table des Matières
loading

Table des Matières