Installing the cooling unit

6.1

Battery monitor

The cooling device is equipped with an electronic device to protect against revers-
ing the polarity when connecting to a battery. To protect the battery, the cooling
device switches off automatically if the voltage is insufficient (see following table).
Devices without TEC control
Connection voltage
12 V
24 V
Devices with TEC control
Connection voltage
12 V
24 V
7
Installing the cooling unit
!
WARNING!
The installation may only be performed by a qualified technician.
7.1

Tools required

For installation and assembly, you will need the following tools:
• Drill
• Screwdriver
• Open-ended spanner: 16 mm, 19 mm and 21 mm
• Sealant and PUR foam
• Cable, cable lugs and cable clips
• Ester oil
18
Switch-off voltage
10.4 V
22.8 V
Switch-off voltage
10.7 V
22.0 V
Coldmachine
Restart voltage
11.7 V
24.2 V
Restart voltage
13.0 V
26.0 V
EN