CALIBRATION

Calibration is useful when the motor is unable to completely open the lock.
This procedure enables the motor to carry out an opening cycle, determining the lock end stop.
Calibration is carried out as follows:
Press the door status sensor to engage the deadbolts.
1
Open the door.
2
Press the door status sensor to engage the deadbolts.
Wait 10 seconds.
3
N.B.: carry out the following steps within 10 seconds:
Open the lock completely (latchbolt and deadbolts) using the handle or
key.
4
Release the handle.
5
Press the door status sensor to engage the deadbolts.
Open the lock completely (latchbolt and deadbolts) using the handle or
key.
6
Release the handle.
7
Press the door status sensor to engage the deadbolts.
8
Press the opening button.
The lock will emit a sound signal lasting 3 seconds and then begin calibration.
The motor will carry out an opening/closing cycle.
Once calibration has finished, open the lock again using the motor to check that the latchbolt
does not protrude more than 1.5 mm.