E. If The pan belt is broken
1.
Turn off the mains power.
2.
Loosen the screws (A)
3.
Loosen the screws (C).
4.
Unplug all the connect wires over the belt.
5.
Change a new belt (D), put the belt around the axis gear and motor gear.
6.
Plug all the connect wires back upon the belt.
7.
Tighten all the screws.
F. If The tilt belt is broken
1.
Turn off the mains power.
2.
Loosen all the screws (A) and open the right arm cover (B).
3.
Loosen the screws (C) that fix the bridge.
4.
Change a new belt (D). Please adjust the tension of the belt properly.
Note: do not fix the belt too tight as it is can easily rupture.
5.
Reverse the procedures from step 3 to 2.
10.

10.MAINTENANCE AND CLEANING

Maintenance:
Ignitor
A. As the pictures shown above, please replace the cable or cable joints immediately once they've turned
yellow.
B. Do maintain the fixtures every two months and make sure that all the screws and terminals have been locked
firmly to make sure the normal performance of the fixtures. Negligence of maintenance would cause
malfunction of the fixture.
Cleaning:
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize
light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause greater accumulation of dirt on the unit's optics.
 Clean with soft cloth and use normal glass to clean liquid.
 Always dry the parts carefully.
 Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
open the cover (B).
Ballast
Filter
45