DESCRIPTION OF THE PRODUCT
2
CONTROL BOARD FEATURES
The VIVO-D102/ VIVO-D102M control board is built to
motorise doors and gates using the IZAR or MAXI
operator with encoder.
This control board has a torque limitation system to
adjust the impact forces to the required values.
General features
• Power supply:
D102: 230Vac, 50Hz; D102M: 125Vac, 60Hz
• Control of open/close by way of encoder
• Maximum thrust, independently adjustable, for
opening and closing
• Adjustable standby time in automatic cycle
• Opening and closing safety device cable connectors
(strips or photocells)
Notable features
Self-testing of photocells (programmable)
The control board tests the photocells before starting
each closing operation. Should a failure be detected,
the operation is not carried out.
STOP pushbutton (emergency stop)
This control board allows an em ergency stop
pushbutton to be installed (STOP). This pushbutton is of
NC type (normally closed). The opening of these
contacts produces the immediate halting of the door.
The operators with release devices are fitted with a
release switch which must be connected to the STOP
cable connectors.
Garage light (programmable)
The garage light time can be programmed between 3
and 240 seconds. Time begins to count when the
operation starts.
Flashing light
(voltage free output)
The light remains on during the opening and closing
operations.
The light goes off when the operation finishes. The light
goes off whenever operation is interrupted at an
intermediate point.
36
Installation Manual
It is also fitted with a start-up and softstop system
which reduces speed at the start and end of the
opening and closing operations, in order to improve
safety and operation smoothness.
The VIVO-D102/VIVO-D102M control board, along
with the IZAR or MAXI operator with encoder, allow
Standard EN 12453:2017 to be met.
• Cable connector for emergency stop pushbutton
(STOP)
• Connector for plug-in receiver
• Connector for traffic light card (AEPS1-001)
• Soft startup and slowdown system
• 24Vac output for peripheral connection
• Emergency battery input (24V)
Traffic light
A traffic light can be connected if the AEPS1-001 card
is installed. Using colour lights, this will indicate the
suitability or otherwise of crossing the door.
• Off: door closed
• Green light: door open, free passage.
• Red light: door in movement, passage forbidden.
• Flashing green light: open door about to close in
automatic mode.
SCA Light
A 24V SCA light can be connected.
• The light remains off when the door is closed.
• The SCA light remains on statically when the door is
open.
• During opening, the SCA light flashes every second.
• During closing, the SCA light flashes every half a
second.
Slowdown function (programmable)
Function which reduces the speed of the motor at the
end of the opening and closing operations. Both
softstop speed and distance can be programmed.
Reset (rS)
Reset is the closed door position search at slow speed.
The display shows rS.
The operator carries out a reset in the following cases:
• When the electricity supply is restored following
interruption, and a key device is activated.
• When the STOP contact opens and closes again.
• When the door collides with an obstacle three
consecutive times.