DESCRIPTION OF THE PRODUCT

1

CONTROL BOARD APPLICATIONS

Operator
Power supply (V/Hz)
Single phase operators up
to 1/4 CV
Single phase operators up
to 1/2 CV
SKY (KSM20)
SIRIUS SI210C(D)
SIRIUS SI510C(D)
ORION
a
RINO
a
TORO
a.
Use the instructions manual for the corresponding operator
O
For correct operation, ensure that DIP7 is "OFF"
if the operator does not have an encoder, or
"ON" if an encoder is fitted.
2

CONTROL BOARD FEATURES

General features
• Power supply (earthed):
AM600S, AM606S: 230Vac/ 50Hz
AM600SM, AM606SM: 125Vac/ 60Hz
• Control of run by time or encoder (for ORION and
RINO motors only) and limit switches
• Adjustable maximum thrust
• Adjustable standby time in automatic cycle
Notable features
Self-testing of photocells (programmable): the
control panel tests the photocells before starting each
operation. Should a failure be detected, the operation
is not carried out.
Garage light (programmable): the garage light time
can be programmed between 3 and 90 seconds. Time
begins to count when operation starts.
Flashing light: the flashing light comes on during the
movement of the gate. The light goes off when the
movement stops.
AM600S
AM606S
AM600SM
(F1: 2.5A)
(F1: 6A)
230/50
230/50
YES
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
YES
NO
NO
YES
AM606SM
(F1: 4A)
(F1: 10A)
125/60
125/60
YES
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
YES
NO
NO
YES
It is necessary to install additional safety items
(photocells or strips) in order to fulfil the
requirements of Standard EN 12453.
• Opening and closing safety device cable connectors
(photocells or mechanical strips)
• Cable connector for emergency stop pushbutton
(STOP)
• Connector for plug-in receiver
• Connector for traffic light card
• 24Vdc cable connector for peripheral connection
• Self-testing of photocells (DIP6 and DIP9)
Traffic light: a plug-in receiver can be connected if the
AEPS1-001 card is installed. Using colour lights, these
will indicate the suitability or otherwise of crossing the
gate.
• Off: gate closed
• Green light: gate open, free passage
• Red light: gate in movement, passage forbidden
• Flashing green light: open gate about to close (in
automatic mode)
Operation advance warning function (DIP2=ON):
this function delays the start of operation by three
seconds, during which time the flashing light comes on
to warn us that operation is about to begin.
AM600S and AM606S control
boards are built to form part of
an automatic door and gate
system, driven by way of a
s i n g l e p h a s e m o t o r ( w i t h
permanent capacitor).
The attached chart shows the
operators for which the control
boards are suitable.
The location of F1 is
indicated
in
"Failure
diagnosis" on page 30.
Control board AM600S-AM606S