Pedestrian Open/Close Programming; Selection Of The Modes And Control Board Functions (Sw2) - Erreka AM600S Manuel De L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PROGRAMMING AND STARTUP
4

PEDESTRIAN OPEN/CLOSE PROGRAMMING

Start programming mode
Programme the slowdown start points
Finish the programming mode
The pedestrian opening and closing of the gate
will be memorised.
The positions in which the gate begins to slow
down, both on opening and in closing, will also
be memorised.
5

SELECTION OF THE MODES AND CONTROL BOARD FUNCTIONS (SW2)

Using SW2, choose the required options (see "SW2 Functions during use (DIP1=OFF)" on page 25).
28
Installation Guide
1 Close the gate by pressing PUL1.
2 Ensure that DIP7 is "OFF" if the operator does not
have an encoder, or "ON" if an encoder is fitted.
If the encoder is not enabled (DIP7=OFF),
operation times will be memorised.
3 Place DIP8 in "ON" (slowdown).
4 Place DIP1 and DIP3 in "ON"; DIP2, DIP4, DIP5 and
DIP6 in "OFF".
DL3
lights
up,
programming mode.
1 Start to open the gate: press ST2; the gate begins
to open.
2 Start slowdown in opening: press ST2 (or A.P. or
the transmitter) at the point chosen for the start of
slowdown (DA1).
3 Finish the pedestrian opening: press ST2 at the
required position for the end of pedestrian opening
(DC1).
4 Start closing the gate: press ST2; the gate begins
to close.
5 Start slowdown in closing: press ST2 (or A.P. or
the transmitter) at the point chosen for the start of
slowdown (DC1).
6 Wait for the gate to come to a halt due to the
action of the closing limit switch.
1 Place DIP1 and DIP3 in "OFF".
DL3 will remain off.
indicating
that
it
is
in

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Am606sAm600smAm606sm

Table des Matières