STARTING UP AND PROGRAMMING
1
CONNECTION TO THE GRID
1 Connect the control board to the electricity supply:
the display should show the sign ?.
Reset (rS): after connecting the electricity power
supply and activating any of the key devices, the
door closes to the stopper, with the stopper being
assigned the position "door closed".
2
DISPLAY
D1:
Display Menus
D2:
Display Parameters
D3 - D4: Display parameter value
The display goes off following a long period
without pressing any key on the control
board. Press the ENTER key to reactivate.
46
Installation Manual
CHANGE OF TURNING DIRECTION: if, when
carrying out the reset (rS), the gate opens instead of
closing, it is necessary to change the turning
direction by programming parameter C1 (see "Prior
Conditions Programming (D1= "C")" on page 47).
During programming, ensure there is no
person or object in the radius of action of the
door and the operation mechanisms.
Indications during operation:
D1 and D2:
CL
(static)
Door closed
CL
(flashing)
Door closing
OP
(static)
Door open
OP
(flashing)
Door opening
XX
(countdown)
Door on standby
STOP
Operator unlocked
PA
(static)
Pause (operation not complete)
rS
(static)
Door searching for close position
D3 and D4:
C4
Opening safety device (pedestrian door)
activated
C5
Closing safety device activated
E1
Encoder motor halted
F1
Thrust limit exceeded
bA
Battery working
Ftço
Photocells defective (pre-testing)
Indications during programming
D1 (Menus): Shows the selected menu. The following
menus are available:
C
Prior Conditions menu
P
Programming menu
F
Main Functions menu
A
Advanced Functions menu
ç
Operation Counter
D2 (Parameters):
Shows each parameter of the selected D1 menu.
D3 - D4 (Parameter Values):
Shows the value or option of the selected D2
parameter.