Total Open/Close Programming - Erreka AM600S Manuel De L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3

TOTAL OPEN/CLOSE PROGRAMMING

The programming of the gate open/close is done
using the transmitter, the ST1 mini-pushbutton or
the total key command (A.T.).
Start programming mode
Programme the slowdown start points
Finish the programming mode
The total opening and closing of the gate will be
memorised.
The positions in which the gate begins to slow
down, both on opening and in closing, will also
be memorised.
PROGRAMMING AND STARTUP
Before making the programming, ensure there
is no person, animal or object in the radius of
action of the gate and the mechanism.
1 Close the gate by pressing PUL1.
2 Ensure that DIP7 is "OFF" if the operator does not
have an encoder, or "ON" if an encoder is fitted.
If the encoder is not enabled (DIP7=OFF),
operation times will be memorised.
3 Place DIP8 in "ON" (slowdown).
4 Place DIP1 and DIP2 in "ON"; DIP3, DIP4, DIP5 and
DIP6 in "OFF".
DL3
lights
up,
programming mode.
1 Start to open the gate: press ST1; the gate begins
to open.
2 Start slowdown in opening: press ST1 (or A.T. or
the transmitter) when the opening limit switch
magnet is approximately 50 cm from the end of the
run, in order to start slowdown (DA1).
3 Wait for the gate to come to a halt due to the
action of the opening limit switch.
4 Start closing the gate: press ST1; the gate begins
to close.
5 Start slowdown in closing: press ST1 (or A.T. or
the transmitter) when the closing limit switch
magnet is approximately 50 cm from the end of the
run, in order to start slowdown (DC1).
6 Wait for the gate to come to a halt due to the
action of the closing limit switch.
1 Place DIP1 and DIP2 in "OFF".
DL3 will remain off.
indicating
that
it
is
Control board AM600S-AM606S
in
27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Am606sAm600smAm606sm

Table des Matières