Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

START UP AND PROGRAMMING
3

PROGRAMMING SEQUENCE

Display
off
ENTER
á
or
indicating
à
CL
Before entering the programming menus, it is
necessary to close the gate or disconnect the device
and then reconnect.
Press the ENTER button to access the programming
menus.
The display shows "C"1 01 or "C"1 0 2.
Use the keys ^ and
and confirm by pressing ENTER.
Use ESC to go back to the previous display.
To leave the programming menu, press ESC several
times until the display goes off or shows CL.
Initial Conditions Programming (D1= "C")
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
C flashing. Press ENTER to confirm. D2 flashes.
D1
D2
Parameter
C
1
Motor turning direction
4
Opening safety device (photocell
or strip)
5
Closing safety device (photocell
or strip)
60
Installation Manual
General navigation through the programming parameters and menus
D1
C
ESC
Select the value
using ^ and
V
to select the required values,
V
until D1 shows the letter
V
D3
0
0
0
1
1
0
1
1
D2
ENTER
á
1
ESC
à
Select the value
using ^ and
V
1 Programme the prior conditions (see "Initial
Conditions Programming (D1= "C")" on page 60).
2 Record the pedestrian and total opening radio
codes, along with the gate open/close (see "Radio
code programming (only with RSD) and gate open/
close programming (D1= "P")" on page 61).
3 Programme the functioning mode, automatic
standby time and pedestrian opening (see "Main
Functions Programming (D1= "F")" on page 61).
4 Programme the advanced functions (see "Advanced
Functions Programming (D1= "A")" on page 62).
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
5 Press ESC to return to the previous display.
Option
D4
default
1
x
2
0
x
0
1
0
x
0
1
D3 - D4
ENTER
á
0 X
ENTER
(confirming)
à
Select the value using
^ and
ESC
(unconfirmed)
à
until the required D2
V
until the required D3 and
V
Options
Device not installed
Device without testing
Device with testing
Device not installed
Device without testing
Device with testing
V

Publicité

Table des Matières
loading

Table des Matières