Problem
The air is not always
cool or hot during
operation
The air does not feel
warm enough during
heating operation
The unit is not
blowing out air
The electric heating
feature does not work
Temperature display
flashes
Possible Causes
The heat pump is not
producing hot air.
The Smart Fan Auxiliary
Controls may be set to
continuous fan.
The heat pump alone
produces air that feels
cooler than desired.
The Smart Fan Auxiliary
Controls may be set to cycle.
The power cord is not
firmly attached.
The compressor may
have failed.
What To Do
• This is normal. The heat pump will produce warm air
but not as hot as air produced when the higher-cost
electric heat is used.
• This causes the fan to blow room temperature air
even when the compressor or heater cycles off.
The continuous air movement provides better
overall temperature control in the cool mode.
See Smart Fan – Cooling/Heating on page 5.
• Use the Electric Heat Option. This turns off the
heat pump and warms with electric heat only.
NOTE: Use of this option will result in increased energy
consumption.
• See Smart Fan – Cooling/Heating on page 5.
• Remove the room cabinet and make sure that the
yellow connector on the end of the power cord is
firmly engaged.
• Set the operation control to STOP and then restart
the unit. If the flashing light reappears within
30 minutes, call for service.