Given below are the control and/or maintenance operations for correct stove use and operation.
Parts / Period
Type of cleaning
Brazier
Ash compartment-pan
Glass
Baffle - fume exchanger
Manifold - fume extractor
Glass - door seal
Pipe - flue connection

5.1 Cleaning the brazier

Remove the brazier and the ash deposited in the combustion chamber and brazier holder. A suitable vacuum
cleaner may be used for this purpose. This operation must be carried out daily, especially in case of accumulated
unburnt matter, to ensure perfect combustion conditions, since the brazier holes allow the flow of combustion air.
Brazier dirty
5.2 Cleaning the ash container
The ash container is located directly under the brazier - brazier holder. To clean it, open the fire door and remove
the ash and any combustion residuals using a suitable vacuum cleaner.
The door must be closed after cleaning. The ash container can be cleaned every 2-3 days depending on stove use.
5.3 Cleaning the glass and air slots
The glass can be cleaned using a damp cloth and specific non-abrasive detergents.
Special slots between the glass, glass stops and fire door at the top and bottom allow air to circulate on the inside
surface of the glass. These slots must be kept clean of any deposits of ash and dust. Therefore periodically clean all
around the the inner side of the glass.

5.4 Cleaning the fume extractor and combustion chamber

The combustion chamber must be cleaned at least once a year, removing all combustion residuals from the internal
baffles and flueways. To do this, remove the cover and the top front panel of the stove. Remove the cast iron
exchanger by undoing the fixing screws then clean the baffles and the chamber.
Also make sure to clean the fume extractor located under the chamber, accessed by removing the inspection port
located on the front lower part of chamber.
Every 3-4 months clean the inside walls (insulating-refractory) of the combustion chamber using suitable
equipment (brushes) and replace them if necessary.
Every 1800 hours of operation or 2000 kg pellet, by means of a message 'SERVICE DUE', the stove signals the
need for extraordinary maintenance (not under warranty) to be performed by qualified personnel who will carry out
complete cleaning and reset the message.
Any knocking or forcing can damage the fume extractor, making it noisy during operation; therefore it is
advisable to have this operation carried out by qualified personnel.
5.5 Cleaning the air flow meter
The air flow meter (it measures the flow of combustion air) installed inside the inlet pipe requires periodical internal
cleaning every 3-4 months, using suitable equipment (blowing compressed air or suitable brushes).
5.6 Cleaning the ceramic surfaces (ceramic models)
The ceramic tiles are handicraft products and therefore may have minor surface imperfections such as tiny spots or
slight colour differences. It is advisable to use a soft dry cloth to clean the ceramic surfaces; the use of detergents
could highlight any flaws.
1 day
2-3 days
routine
routine
cleaning
cleaning
Brazier clean
Brazier Holder clean
(not installed)
1 month
2-3 months
routine
cleaning
42
1 year
extraordinary
routine
cleaning: carried out
cleaning
by the Service Centre
The brazier must rest on the brazier
holder and precisely on the entire
ring band without air gaps.
EVA-