The Info Menu Item; Info; Measured Values Lt Status Grid Status - Fronius Galvo 1.5-1 208 Instructions De Service

Masquer les pouces Voir aussi pour Galvo 1.5-1 208:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The INFO menu item

INFO

Measured values
Measured values Display range:
LT status
Grid status
LT status
Grid status
32
PV Ins.
Insulation resistance of the PV system
(for ungrounded solar modules and for solar modules grounded at the
negative pole)
Fan #1
Percentage value of the fan's target power
U PV1
Current DC voltage at the terminal, also if the inverter is not feeding
in at all (from the first MPP Tracker)
The status display of the last error that occurred in the inverter can be
shown.
IMPORTANT! Status codes 306 (Power low) and 307 (DC low) ap-
pear naturally every morning and evening due to low solar irradiance.
These status codes are not the result of a fault.
-
After pressing the "Enter" key, the power stage set status and the
last error that occurred are displayed
-
Use the "Up" and "Down" keys to scroll through the list
-
Press the "Back" key to exit the status and error list
The last 5 grid errors that occurred can be displayed:
-
After pressing the "Enter" key, the last 5 grid errors that occurred
are displayed
-
Use the "Up" and "Down" keys to scroll through the list
-
Press the "Back" key to exit the grid error display
INFO
(information on device and software)
PV Ins. / Fan #1 / U PV1