BFT IGEA BT Instructions D'installation page 23

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
First turn the key clockwise, then rotate the release knob to free the gate.
The knob is to be rotated anticlockwise in the case of a left-hand leaf, clockwise
in the case of a right-hand leaf.
Keep the knob in its release position by turning the key further. Push the leaf
slowly to open or close the gate.
To reactivate motor-driven operation, free the knob from its release position and
bring it back to its initial position for normal operation.
11) AUTOMATION CHECK
Before allowing the automation to be used normally, carry out the following
procedure very carefully:
Check the correct functioning of all safety devices (limit microswitches,
photocells, sensitive edges etc.).
Check that the thrust (anti-squash) force of the leaf is within the limits set by
current regulations.
Check the manual opening command.
Check the opening and closing operations with the control devices in use.
Check the standard and customised electronic functioning logic.
12) AUTOMATION OPERATION
Since the automation can be remote-controlled by means of a remote control
device or a start button, and so out of sight, the good working order of all the
safety devices should be checked regularly. In the event of any anomalous fun-
ctioning of the safety devices, consult a specialised technician immediately. Keep
children at a safe distance from the automation operation area.
13) CONTROL
The automation is used for the power-operated opening and closing of the
gate. The control can be of a number of types (manual, remote-controlled, magnetic
badge access control, etc.) depending on requirements and the characteristics
of the installation. See the specific instructions for the various control systems.
Users of the automation must be instructed about its control and operation.
14) MAINTENANCE
Disconnect the power supply when carrying out any maintenance operations.
Lubricate the IGEA-BTs of the manoeuvring arm regularly.
Clean the lenses of the photocells every so often.
Have a specialised technician (installer) check the adjustment of the electric
clutch.
In the event of any anomalous functioning which cannot be resolved, discon-
nect the power supply and contact a specialised technician (installer). Whilst
the automation is out of order, activate the manual release to allow manual
opening and closing.
INSTALLATION MANUAL
23
IGEA-BT -

Publicité

Table des Matières
loading

Table des Matières