GRAUPNER ULTRAMAT 14 plus Instructions D'utilisation page 41

Chargeur rapide à grande puissance piloté par micro-processeur pour la charge rapide des accus nicd, nimh, lipo/liio/limn/life et des accus pb
Masquer les pouces Voir aussi pour ULTRAMAT 14 plus:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Input voltage and Battery resistance display
INC
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
I n p u t
V o l t a g e
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1 3 . 6 2 V
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Battery Res.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
25m
The battery resistance is messured 5min after starting manual charging (NiCd, NiMH), end of
manual charging (NiCd, NiMH) and 2min after starting manual discharge (NiCd, NiMH).
The battery resistance is one important value to determine the battery quality.
Press any button to return to the menu system.
INC
DEC
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
I n p u t
V o l t a g e
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1 3 . 6 2 V
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Battery Res.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
25m
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1 .
4 . 1 5 3 V
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2 .
4 . 1 6 8 V
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3 .
4 . 0 5 3 V
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4 .
0 . 0 0 0 V
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5 .
0 . 0 0 0 V
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6 .
0 . 0 0 0 V
The current input voltage and battery resistance can be
DEC
called up at any time by pressing the INC and DEC
buttons simultaneously.
Change the display with INC or DEC button to input
voltage, the battery resistance display (only in NiCd- and
NiMH- manual modes) and to the single cell voltages and
backwards.
Displaying the Input voltage can be very useful if you are
using your car's battery as energy source for charging.
Display the voltage of the single cells
The current input voltage and battery resistance can be
called up at any time by pressing the INC and DEC
buttons simultaneously.
Change the display with INC or DEC button to input
voltage, the battery resistance display (only in NiCd- and
NiMH- manual modes) and to the single cell voltages and
backwards.
Displaying the single cell voltages is useful to check the
single cell voltages.