Pc Interface - GRAUPNER ULTRAMAT 16 S Instructions D'utilisation

Chargeur rapide à grande puissance piloté par micro-processeur pour la charge rapide, la décharge et le cyclage des accus nicd, nimh, lipo/liio/limn/life et des accus pb
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
* * * * * E R R O R * * * * * *
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
b a l . v o l t
t o o
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
* * * * * E R R O R * * * * * *
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
b a l . v o l t
t o o
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
* * * * * E R R O R * * * * * *
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
o p e n
b a l a n c e r
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
* * * * * E R R O R * * * * * *
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
o p e n
b a l a n c e r
You can download the appropriate USB serial driver
at www.graupner.de product search 6468.
Connect the USB lead to the charger and to a free USB port on your PC.
PC software can be downloaded at www.graupner.de or www.logview.info.
This software enables you to display battery curves and much more.
If the charger detects an excessive cell voltage at the
balancer input, this error message appears.
h i .
The error message appears at the following voltages:
LiPo > 4.3 V, LiIo > 4.2 V, LiFe > 3.9 V, NiCd / NiMH > 2.0 V
This error message may also appear if the cells
connected to the charger are overcharged.
If the charger detects an excessively low cell voltage at
the balancer input, this error message appears.
The error message appears at the following voltages:
l o w
LiPo < 2.75 V, LiIo < 2.75 V, LiFe < 2.0 V, NiCd / NiMH <
0.1V
If this should occur, we recommend that you give the
battery an initial charge for example in the LiFe Program
Mode for a few minutes (max. five minutes), which allows
cell voltages down to 2.0V without connecting the
balancer plug.
Warning: it may be that the battery contains
damaged cells, and the battery pack must therefore
be monitored very closely while it is being recharged.
As soon as the voltage is high enough, for safety
reasons the battery must always be charged with the
balancer plug connected (explosion and fire
hazard!).
When starting in NiCD/NiMH balance mode, if the
balancing connector is not connected to the balancing
port of the charger, this error should occur.
While the balancing connector is connected to the
balancing port of the charger, if the balancing connector is
disconnected from the balancing port of the charger
during charge or discharge, this error should occur.
When temperature of the charger exceeds 125°C.
18. PC-Interface