GRAUPNER ULTRAMAT 16 S Instructions D'utilisation page 37

Chargeur rapide à grande puissance piloté par micro-processeur pour la charge rapide, la décharge et le cyclage des accus nicd, nimh, lipo/liio/limn/life et des accus pb
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L i P o
m a n u a l
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C : 4 . 0 A
4 0 0 0 m A h
+
-
INC
DEC
ENTER
The charger automatically sets the charge current of 1C based on this information.
When you connect the pack to the charger and start the charge process, the charge current
starts at 0.00 A and slowly rises to the set limit.However, please do not be surprised if the
charger does not reach the current you have set, because the charge program constantly
monitors the battery voltage in order to prevent the pack inflating, provided that the voltage of
the individual cells in the pack is the same.When the charger automatically reduces the charge
current, the screen displays the message END, alternating with the reduced charge current.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L i P o
d i s c h a r g e
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1 . 0 0 A
2 . 5 V / c e l l
+
-
INC
DEC
ENTER
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L i P o
s t o r e
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2
sec.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
< 2 . 0 A
3 . 8 0 V / C
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
+
-
INC
DEC
ENTER
Lithium manual program
This program charges the battery using the capacity
(charge current) which you set.
Before you initiate the actual program you must set the
charging current (range 0.1A...10.0A, left of the screen)
+
-
and the capacity of the pack (range 50...9900 mAh, right
INC
DEC
on the screen) using the INC / DEC buttons. Switch
between the charge current and the capacity parameters
by using the ENTER button.
If the charged capacity reaches 110% of the adjusted
capacity, the charging process is stopped for safety
reasons.
Lithium discharge program
The purpose of this program is to determine the residual
capacity of a Lithium pack which has not been fully
discharged.
+
-
The program discharges the pack using the set discharge
INC
DEC
current (0.1 ... 5.0 A, left of screen) down to the set final
discharge voltage (2.5 ... 3.7 V per cell, right of screen). It
is not possible to set a final discharge voltage below 2.5 V
per cell, otherwise the battery will suffer permanent
damage.
Lithium storage program
This program does charge or discharge the battery to the best
storage voltage.
The program does charge or discharge the battery to the
adjusted storage voltage, which is best for longer storage of
a Li-battery.
Best store voltage:
LiPo: 3,8...3,9V/cell
+
-
LiIo: 3,7...3,8V/cell
INC
DEC
LiFe: 3,3...3,4V/cell
37

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

6468

Table des Matières