4 4 . . R R e e s s i i d d u u a a l l g g o o l l d d d d e e p p o o s s i i t t i i o o n n
The unit starts the electroforming process automatical-
ly when the gold electrolyte reaches the required
temperature. Until this temperature is reached, errors
can be corrected by pressing the Start/Stop key to
interrupt the heating-up process. The operation indica-
tor lights up during the electroforming process. The
sponge takes on a darker colour.
Press the timer button to clear the previous settings.
The unit is then ready for the next deposition operation.
When the residual gold deposition process is complete
(status display is reset to 000, operation indicator is
off), remove the copper rods from the contacts. Push
the electroforming head upwards, allow the head and
the residual gold sponge to drip dry and then remove
them.