3.12.d Setting the unit of measurement of temperature
it is possible to choose the set and environment temperature unit of measurement choosing between °C
(Celsius) or F (fahrenheit).
Work as follows:
-
On the control panel, press the keys + and - at the same time for approximately three seconds.
the desired unit of measurement appears on the display of the control panel.
On the remote control, keep the central key TEMP pressed for approximately three seconds.
-
the desired unit of measurement appears on the display of the remote control.
The unit of measurement change must be performed both on the control panel and on the remote
control.
3.12.e Directing the air flow
• This function can be activated only from the remote control.
a. When the appliance starts, the flap opens completely.
b. Press the key "SWING" on the remote control and the flap starts oscillating automatically.
c. Press the key "SWING" to stop the flap in a certain position.
Press it again to restart oscillation.
3.12.f Short Cut function
• This function can be activated only from the remote control.
a. When the appliance is running in any of its modes, press the key "SHORT CUT" on the remote control
and the appliance automatically configures itself to "AUTO" with a set temperature of 26°C (80 f).

3.12.g Auto-Restart

a. If the appliance switches off due to interruption of power supply, it automatically restarts with the previous
settings when electrical power is restored.

4 - MAINTENANCE AND CLEANING

Before proceeding with any maintenance and cleaning
intervention, always make sure you disconnected the
power plug from the power socket.
Do not touch the metal parts of the appliance when you
remove the filter.
There is a risk of injury due to the sharp metal edges.
Do not use water to clean the internal parts of the air conditioner.
Exposure to water can ruin the isolation, with the risk of electric shocks.
EN - 29