E L E C T R I C A L C O N N E C T I O N
The heater is designed for permanent connection to a wall jack
or socket.
The device is connected to the AC mains system by putting the
power cord into a connection socket.
NOTE
The connecting cable can be extended using a cable of the
H05VV-F3G1,50 type. A direct connection to a permanently laid
cable may only be implemented up to a diameter of 1.5 mm²
(e.g. NYM-J3G1,5 mm²). The length of the connecting cable
must be between 1.0 and 1.9 m.
An all-pole disconnecting device with a minimum contact open-
ing width of 3 mm has to be mounted into the fixed electrical
installation in compliance with the installation regulations.

HEATING MODE

The heater is operated by means of direct connection via
switch, via an external room thermostat, via timer or controller
directly on the device or via a radio receiver in connection with a
radio-controlled room thermostat. These items can be ordered
as accessories. Please observe the operating instructions
of the respective product.
U S E R M A N U A L
HEATING MODE
®
The LAVA
BATH infrared heating has a very large radiation
component and a very small convective component of the heat-
ing power. For reasons of safety, the surface temperature is
max. 70 °C, therefore LAVA
ing and thanks to the included towel holder as towel heater as
well.
The LAVA
BATH infrared heating by ETHERMA mainly heats
®
solid objects and, only to a lesser extent, directly heats the
room air. Therefore, these devices are ideal for additional tem-
perature control.
Depending on the size of the device, the LAVA
heating requires a certain time until the operating temperature
is reached. Only then the radiation can take its full effect.
The glass panel produced for the product consists of 6 mm
single-pane safety glass (ESG). This is much more resistant
12
®
BATH suits ideally as zone heat-
®
BATH infrared
Dimensional drawing: Connection circuit diagram
ATTENTION:
If the main cable to the device is dam-
aged, it must be replaced immediately by a spe-
cialist.
in contrast to conventional glasses and is designed for signif-
icantly higher impact forces. Nevertheless, you should avoid
excessive stress. In case of damage, ESG shatters into many
small parts with blunt edges, so that the risk of injury is min-
imized. When choosing the place of installation, please note
that a negligible amount of tempered glass still causes a so-
called "spontaneous breakage", which means that the glass
shatters even without external influence. Therefore, choose
the installation location of the device in such a way that even in
these cases no danger to persons or objects is to be expected.
MAINTENANCE AND CARE
The LAVA
BATH infrared heating is designed so that it gives off
®
its heat via the surface in the form of radiation. The device does
not contain any parts requiring special maintenance. In order
to service your infrared heater, we recommend using a damp
cloth. Please do not use any scouring agents, since they may
leave scratch marks on the surface.
ATTENTION:
When you want to clean the LAVA
BATH infrared heating, the heating device must be
cold!
®