8. CONNECTING THE CINDERELLA GAS TOILET

8.1 CONNECTING THE GAS SUPPLY

NB!
This toilet may only be connected to the gas supply by a specialist in accordance with the technical and
administrative regulations of the country in which the toilet is installed.
Only operate the toilet at the pressure shown on the type plate on the back of the toilet.
Only operate the toilet with the type of gas shown on the type plate on the back of the toilet.
Use a metal-sealed screw connection when connecting the gas
Use flexible gas piping to ensure that the installation remains in a tensionless state (not included in the
scope of the delivery).
Have a leak test and a flame test performed by an authorized specialist after professional installation.
Ensure you are issued with a certificate of inspection.
Fuel consumption pr.hour
Inlet gas pressure
Toilet gas connection
Brass fitting - straight coupling
Brass fitting, 90° elbow female/female
Imperial
0.449 (lb/hour)
8-20 Inches WC
1/4" NPT female
1/4'' x 1/2'' NTP
1/2'' x 1/2'' NPT
Metric
0,204 (kg/hour)
20-50 mbar
Gas connection :
1/4" NPT female