8. CONNECTING THE CINDERELLA GAS TOILET
8.1 CONNECTING THE GAS SUPPLY
NB!
•
This toilet may only be connected to the gas supply by a specialist in accordance with the technical and
administrative regulations of the country in which the toilet is installed.
•
Only operate the toilet at the pressure shown on the type plate on the back of the toilet.
•
Only operate the toilet with the type of gas shown on the type plate on the back of the toilet.
•
Use a metal-sealed screw connection when connecting the gas
•
Use flexible gas piping to ensure that the installation remains in a tensionless state (not included in the
scope of the delivery).
•
Have a leak test and a flame test performed by an authorized specialist after professional installation.
Ensure you are issued with a certificate of inspection.
Fuel consumption pr.hour
Inlet gas pressure
Toilet gas connection
Brass fitting - straight coupling
Brass fitting, 90° elbow female/female
Imperial
0.449 (lb/hour)
8-20 Inches WC
1/4" NPT female
1/4'' x 1/2'' NTP
1/2'' x 1/2'' NPT
Metric
0,204 (kg/hour)
20-50 mbar
Gas connection :
1/4" NPT female
11