accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured Green-and-Yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the symbol
or coloured Green or Green-and-Yellow. The
wire which is coloured Blue must be connected
to the terminal which is marked with the letter N
or coloured Black. The wire which is coloured
Brown must be connected to the terminal which
is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site
not be suitable for the plug supplied with your
product, the plug must be removed (cut off if it is
moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used
without a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 12A and approved to
BS 1362.
3. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable water supply only.
Note: A plumbing permit and services of a licensed
plumber may be required in some areas.
* The connections to the mains water supply
must be made in accordance with the countries'
current requirements of the Water Supply or
Water Fittings Regulations.
* Water supply pressure should be minimum 0.05
MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
If the pressure exceeds 0.8 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
back the supply tap.
* The icemaker drain is gravity flow, so ensure
drain pipe has an adequate pitch or fall.
* Water should drain into an open trap.
* Drain lines should not be piped directly to the
sewer system. A vertical air gap of a minimum
of 5 cm should be between the end of the drain
pipes from the icemaker and the storage bin and
the floor drain.
* Water supply connection is intended to be made
by means of a pipe, not a hose set.
II. OPERATING INSTRUCTIONS
WARNING
1. This icemaker is designed to produce and
store edible ice. To keep the icemaker
hygienic:
* W a s h y o u r h a n d s b e f o r e r e m o v i n g
ice. Use the plastic scoop provided
(accessory).
* The storage bin is for ice use only. Do not
store anything else in the bin.
* Clean the storage bin before use (see "III.
1. CLEANING").
* Keep the scoop clean. Clean it by using a
neutral cleaner and rinse thoroughly.
* Close the door after removing ice to
prevent entrance of dirt, dust or insects
into the storage bin.
2. T h e u s e o f a n y e l e c t r i c a l e q u i p m e n t
i n v o l v e s t h e o b s e r v a n c e o f s o m e
fundamental rules. In particular:
* Instances of high humidity and moisture
increase the risk of electrical short
circuits and potential electrical shocks. If
in doubt, disconnect the icemaker.
* Do not damage the power cord or pull it
in order to disconnect the icemaker from
the feed network.
* Do not touch the electrical parts or
operate the operation switch with damp