SECTION ONE: GENERAL SAFETY INSTRUCTIONS
GAS AND ELECTRICAL REQUIREMENTS AND GROUNDING INSTRUCTIONS
PLEASE READ CAREFULLY
30" Gas Model:
120 volts, 60 Hz.,
15 Amp electrical circuit required.
36" Gas Models:
120 volts, 60 Hz.,
15 Amp electrical circuit required.
36" model with electric griddle - 20
Amp circuit required.
48" Gas Models:
120 volts, 60 Hz.,
15 Amp electrical circuit required.
48" models with electric griddle -
20 Amp circuit required.
WARNING
ALWAYS DISCONNECT THE
ELECTRICAL PLUG FROM THE
WALL RECEPTACLE BEFORE
SERVICING THIS UNIT.
It is recommended that a dedicated
circuit servicing this appliance be
provided.
The use of gas cooking appliances
results in the production of heat
and moisture.
Safety Precautions
CAUTION
FOR PERSONAL SAFETY,
THIS APPLIANCE MUST BE
CONNECTED TO A
PROPERLY GROUNDED
AND POLARIZED ELECTRICAL
POWER SUPPLY.
See Installation Instructions for electrical requirements and
grounding instructions.
It is the personal responsibility and obligation of you, the user, to have
this appliance connected to the electrical power supply in accordance
with the National Electrical Code and/or applicable local codes and
ordinances by a qualified electrician.
IN CASE OF AN ELECTRICAL FAILURE
If for any reason a gas control knob is turned ON and there is no
electrical power to operate the electronic igniters on the range's
cooktop burners, turn OFF the gas control knob and wait 5 minutes
for the gas to dissipate before lighting the burner manually.
To light the burners manually, carefully hold a lighted match to the
burner ports and turn the gas control knob to HI. During a power
failure you can use the standard cooktop burners, but each must
be lit with a match.
DO NOT attempt to light the two left burners manually. These
burners are equipped with the ExtraLow
manually.
TESTED IN ACCORDANCE WITH:
• ANSI Z21.1 for Household Gas
Appliances
• UL858 for Household Electric
Ranges
• CAN/CSA-22.2 No. 61-M89 for
Household Cooking Ranges
• CAN/CGA 1.1-M81 Domestic
Gas Ranges
SAVE THESE INSTRUCTIONS
CAUTION - ALL MODELS
Check your local building codes for
the proper method of installation.
In the absence of local codes, this
unit should be installed in
accordance with the National Fuel
Gas Code No. Z223.1 current issue
and the National Electrical Code
ANSI/NFPA No. 70 current issue
or the Can - B149 Installation Codes
for Gas Burning Appliances and
C22.1 Canadian Electrical Code
Part 1.
2
CAUTION
Accessible parts may
become hot when the grill
is in use. Young children
must be kept away.
®
feature and cannot be lit

Publicité

Chapitres

loading