Number of
Fault
flashes
5
The appliance
switches off.
6
The appliance
continues to oper­
ate at reduced
power in clocked
operation.
7
The appliance
switches off.
8
The appliance
switches off.
10
The appliance
switches off.
11
The appliance
switches off.
12
The appliance
switches off.
13
The appliance
switches off.
14
The appliance
switches off.
15
Empty plate pro­
tection
Cause
Fractured line at the
power rotary switch
Elevated internal tem­
perature
Sensor faulty.
Mains phase failure
No connection to the
generator.
Hardware initialisation
fault.
Mains current measure­
ment fault
Fault caused by mains
voltage being too high
or too low
Fault with PSU voltage
being too high or too
low
Empty cookware
Mains supply fault or
temperature sensor
faulty.
Action
Contact the authorised Customer
Service agent.
Ambient temperature too high.
Clean air filter.
Check circulation of intake and ex­
haust air.
Contact the authorised Customer
Service agent.
Check phases. Contact the autho­
rised Customer Service agent.
Contact the authorised Customer
Service agent.
Wait - the appliance updates itself au­
tomatically every 30 seconds.
Have the mains connections checked
by a qualified electrician or an autho­
rised Customer Service agent.
Have the mains connections checked
by a qualified electrician or an autho­
rised Customer Service agent.
Have the mains connections checked
by a qualified electrician or an autho­
rised Customer Service agent.
Switch off appliance and wait until
cook top has cooled down.
Turn off master switch before appli­
ance and switch back on again after
a few minutes.
If the fault continues to occur, contact
the authorised Customer Service.
en