- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of
pellets.
- Make sure the stove is off when loading pellets.
- The pellet hopper lid must always remain closed; it must only be opened when loading fuel.
- The bags of pellets must be kept at least 1.5 m from the stove.
4.4.1 Modifying the room temperature setting
To modify the room temperature just select the MODIFY ROOM SET mode by pressing the button P2.
Then use the buttons 'P1' and 'P2' : the display shows the current SET temperature status.
Button 'P1'
Button 'P2'
When the fume temperature rises the maximum value set, the
display will show the message 'MODULA F' ('MODULATION F')
and the stove starts the modulation of the flame authomatically. On
the contrary when the temperature goes over 280°C the display
will show the alarm 'ALARM HOT FUMI' ('ALARM HOT FUMES')
and the stove will start the switch-off procedure.
4.4.2 Modifying the water temperature setting
To modify the water temperature just select the MODIFY WATER
SET mode by pressing the button P1.
Then use the buttons 'P1' and 'P2' : the display shows the current
SET temperature status.
When the water temperature has reached the set value,
as a condition also at the same time as that described in par.4.4.1,
the output is automatically brought
MODULATION status.
As for idro model stove, when the water temperature parameter
can't be reached, the activation of led [ A ] starts.
Room temperature set
value
Dialogue box
to the min. value,
46
Clock
Room temperature
Water temperature set value
Room temperature
Clock
Dialogue
Water temperature
box