The indicator can only be reset by
pressing the reset button after the
light has come on. Pressing the but-
ton at any other time will have no ef-
fect.
When to change the battery in the ra-
dio-control handle
Approximately every 18 months.
One 3 V battery (CR 2032) is required.
The vacuum cleaner can still be used
when the battery has run out or if
there is no battery fitted.
 To do so, switch the vacuum cleaner
on using the On/Off foot control .
The Standby indicator  on the va-
cuum cleaner will light up yellow.
 Press the restart button on the va-
cuum cleaner (dia. 43).
The vacuum cleaner can continue to be
used in this way, but only at maximum
power.
How to change the battery in the ra-
dio-control handle (dia. 44)
 Undo the screw on the battery com-
partment cover using a cross-tip
screwdriver and then remove the
cover.
 Replace the battery with a new one,
making sure the polarity is correct.
 Replace the cover and tighten the
screw back up again.
 Dispose of the old battery in a muni-
cipal recycling facility.

When to change the thread lifters

(not possible on EcoTeQ Plus floor-
heads)
The thread lifters on the suction inlet to
the floorhead can be replaced. Check
them from time to time and replace
them if the pile has worn down.

How to replace the thread lifters

(dia. 45)
 Use a suitable screwdriver to remove
the thread lifters from the slots.
 Fit new thread lifters.
Cleaning the roller on the AllTeQ
floorhead (dia. 46)
 Release the bearing (with bayonet fit-
ting) using a coin.
 Press the bearing out, and remove.
 Remove the roller.
 Remove any threads and hair, replace
the roller and refit the bearing, locking
it back into position.
Replacement parts are available from
your Miele dealer or from the Miele
Spare Parts Dept.

Cleaning and care

Always disconnect the vacuum
cleaner from the electrical supply be-
fore cleaning it. Switch off at the wall
socket and unplug it.
Vacuum cleaner and accessories
The vacuum cleaner and all plastic ac-
cessories can be cleaned with a propri-
etary cleaner suitable for plastic.
en
55

Publicité

Table des Matières
loading

Table des Matières