Warranty - T.I.P. EXTREMA 500/13 Pro Mode D'emploi

Pompe submersible pour eaux usées
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MALFUNCTION
1. The pump is not
1. No current.
discharging any liquid, the
motor is not running.
2. Thermal motor protection feature has
triggered. (for information on operation with
liquids > 50°C, see the note in Technical data).
3. The capacitor is defective.
4. The pump wheel is blocked.
5. The floating switch is defective.
2. The motor is running,
1. The intake openings are clogged.
but the pump is not
2. The pressure line is clogged.
discharging any liquid.
3. Air penetrates into the pump body.
4. The min. suction level was fallen short of;
possibly incorrect setting of the floating switch,
motion of floating switch restricted, floating
switch defective.
5. Check valve (non-return valve), if present, is
blocked or defective.
3. The pump stops after a
1. The electrical supply does not correspond to
short time of operation
the information given on the type plate.
because the thermal
motor protection feature
has triggered.
2. Pump or intake openings are blocked by
solids.
3. Liquid is too viscous.
4. Temperature of the liquid is too high.
5. Pump is running dry.
4. Intermittent or irregular
1. Pump wheel obstructed by solid matters.
operation.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Mains voltage out of tolerance.
5. Motor or pump wheel defective.
5. Water quantity
1. Refer to section 2.1.
discharged by pump is
2. Refer to section 2.2.
inadequate.
3. Worn pump wheel.
6. The pump does not cut
1. Floating switch cannot move freely.
in or out.
2. Incorrect setting of floating switch.
3. Floating switch defective.

9. Warranty

The present device was manufactured and inspected according to the latest methods. The seller
warrants for faultless material and workmanship in accordance with the legal regulations of the country
in which the device was purchased. The warranty period begins with the day of the purchase and is
subject to the provisions below:
Within the period of warranty, all defects which are to be attributable to defective materials or
manufacturing will be eliminated free of charge. Any complaints are to be reported immediately upon
their detection.
The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third
parties. Damage resulting from improper handling or operation, incorrect setting-up or storage,
inappropriate connection or installation or Acts of God or other external influences are excluded from
warranty.
Parts being subject to wear and tear, such as the pump wheel (impeller) and mechanical shaft seals
are excluded from warranty.
POSSIBLE CAUSE
6
ELIMINATION
Please use a device complying with GS (German
technical supervisory authority) to check for the
presence of voltage (safety information to be
observed!). Please verify the correct position of
the plug.
2. Separate the pump from the electrical mains,
allow the system to cool down, eliminate cause.
3. Please contact the customer service
department.
4. Eliminate blocking of pump wheel.
5. Please contact the customer service
department.
1. Remove possible congestion.
2. Remove possible congestion.
3. Start pump several times so that the entire air
will be driven out.
4. Make sure that the minimum suction level is not
fallen short of; if necessary, adjust floating switch
properly or make sure that it can move freely; in
the case of a defective floating switch, please
contact customer service.
5. Eliminate blocking of the check valve (non-
return valve) or replace, if damaged.
1. Please use a device complying with GS
(German technical supervisory authority) to check
the voltage of the lines of the connection cord
(safety information to be observed!).
2. Remove possible congestion.
3. Pump may not be suitable for this liquid. If
feasible, the liquid should be thinned.
4. Make sure that the temperature of the liquid
being pumped does not exceed the max.
admissible value.
5. Eliminate causes of dry-running.
1. Remove solids.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Make sure that mains voltage matches that
indicated on the type plate.
5. Please contact the customer service
department.
1. Refer to section 2.1.
2. Refer to section 2.2.
3. Please contact the customer service
department.
1. See that floating switch can move freely.
2. Correct floating switch settings.
3. Please contact the customer service
department.
13

Publicité

Table des Matières
loading

Table des Matières