Stove switches off.
Alarm displayed is
"AlAr Sec"
Stove switches off,
Alarm displayed is
"AlAr HottEmp"
Stove switches off.
Alarm displayed is
"AlAr Sond"
Stove is in steady con-
dition. Display shows
"Stop FirE
Stove is in steady con-
dition. Display shows
"Stop FirE
Display shows "ont"
1
4
110
Stove is overheated
Fumes outlet tempera-
ture sensor is broken
Electronic circuit board
is broken
The room air recircula-
tion fan is broken
Too high parameter
set
Fumes outlet tempe-
rature sensor discon-
nected
Fumes outlet tempera-
ture sensor is broken
The burning pot needs
cleaning
Cold start whem room
air temperature is be-
low 12°C. Ignitor can
not reach the desired
temperature
Room temperature
below 0°C
Reset the stove by manual reset but-
ton at back of the stove. Possible
cause: too high room temperature.
Open doors to other rooms. If the
problem continues call authorized
Zibro technician
Replace the sensor, Code COM0239.
By authorized Zibro technician only
Replace the electronic circuit board.
Code COM0231.Call a specialised
technician
Replace the fan, code COM0208. By
authorized Zibro technician only
Change relative parameter. By autho-
rized Zibro technician only
Verify the sensor is connected to the
circuit board card By authorized Zibro
technician only
Replace the sensor, Code COM0239.
By authorized Zibro technician only
Stove works at minimum rate. Smoke
gas extraction fan works at maxi-
mum rate, no direct problem. Clean
burning put as soon as possible (see
chapter F.3.4)
Use BBQ fire lighter sticks to ignite
the fire. Continue with restart the
stove when the fire lighter sticks are
burning. Follow the normal proce-
dure.
Not an error. The thermometer is not
able to measure and display negative
temperatures.